Helukabel 12 AWG 5 Cores JB-750 Flexible Colour Coded 750V Meter Marking Bare Copper Conductor Cable 11123

Helukabel 12 AWG 5 Cores JB-750 Flexible Colour Coded 750V Meter Marking Bare Copper Conductor Cable 11123

Select gauge from drop-down menu for prices:

Helukabel 12 AWG 5 Cores JB-750 Flexible Colour Coded 750V Meter Marking Bare Copper Conductor Cable 11123

Product Details

Technical Data:
• Special-PVC control cable adapted to DIN VDE 0285-525-2-11 / DIN EN 50525-2-11 and IEC 60227-5

Temperature Range:
• flexing -15°C to +80°C
• fixed installation -40°C to +80°C

Nominal Voltage:
• U0/U 450/750 V
• fixed installation, under protection
• U0/U 600/1000 V

Test Voltage: 4000 V

Breakdown Voltage: min. 8000 V

Insulation Resistance:
• min. 20 MOhm x km

Minimum Bending Radius:
• flexing 7,5x cable Ø
• fixed installation 4x cable Ø

Radiation Resistance:
• up to 80x106 cJ/kg (up to 80 Mrad)

Cable Structure:
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3
• Core identification to JB/OB colour code
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay-length
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1
• Sheath colour grey (RAL 7001)
• With meter marking

Properties:
• Extensively oil resistant, oil-/chemical resistance see table Technical Informations
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers

Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)

Note:
• G = with green-yellow conductor x = without green-yellow conductor (OB).
• Cleanroom qualification tested with analog type. Please note "cleanroom qualified" when ordering.
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Screened analogue type: Y-CY-JB

Application:
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air, as measuring and control cables in tool machinery, conveyor belts, production lines, as well as in machinery production, in air-conditioning and steel production plants. The earth core is located immediately below the outer sheath. JB cables are suitable for use in all electrical equipment either in dry or damp areas. They should not, however, be installed in the open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

technical specification:
awg-no. 12
no.cores x cross-sec. mm² 5 G 4
outer ø app. - mm 13,9
cop. weight - kg/km 192,0
weight app. - kg/km 361,0
helukabel part number 11123