HW101 Instrumentation Cable 300 Volt UL Type PLTC & ITC, 105°C Single Pair or Triad Shielded PVC Insulation PVC Jacket Copper Conductors - 20 AWG - 1 Triad
Select gauge from drop-down menu for prices:
HW101 Instrumentation Cable 300 Volt UL Type PLTC & ITC, 105°C Single Pair or Triad Shielded PVC Insulation PVC Jacket Copper Conductors - 20 AWG - 1 Triad
- HW101 Instrumentation Cable 300 Volt UL Type PLTC & ITC, 105°C Single Pair or Triad Shielded PVC Insulation PVC Jacket Copper Conductors
- HW101 Instrumentation Cable 300 Volt UL Type PLTC & ITC, 105°C Single Pair or Triad Shielded PVC Insulation PVC Jacket Copper Conductors - 20 AWG - 1 Pair
- HW101 Instrumentation Cable 300 Volt UL Type PLTC & ITC, 105°C Single Pair or Triad Shielded PVC Insulation PVC Jacket Copper Conductors - 18 AWG - 1 Triad
- HW101 Instrumentation Cable 300 Volt UL Type PLTC & ITC, 105°C Single Pair or Triad Shielded PVC Insulation PVC Jacket Copper Conductors - 18 AWG - 1 Pair
- HW101 Instrumentation Cable 300 Volt UL Type PLTC & ITC, 105°C Single Pair or Triad Shielded PVC Insulation PVC Jacket Copper Conductors - 16 AWG - 1 Pair
- HW101 Instrumentation Cable 300 Volt UL Type PLTC & ITC, 105°C Single Pair or Triad Shielded PVC Insulation PVC Jacket Copper Conductors - 16 AWG - 1 Triad
Product Details
HW101 Instrumentation Cable 300 Volt UL Type PLTC & ITC, 105°C Single Pair or Triad Shielded PVC Insulation PVC Jacket Copper Conductors - 20 AWG - 1 TriadTechnical Specifications: | |
Catalog Number | HW101 2001T |
Size AWG | 20 |
Pair or Triad | 1 Triad |
Insulation Thickness Mils | 15 |
Jacket Thickness Mils | 35 |
Overall Diameter Inch | 0.25 |
Net Weight Lbs/Mft | 36 |
Specifications:
- HW101
- Instrumentation Cable
- 300 Volt UL Type PLTC & ITC, 105°C
- Single Pair or Triad
- Shielded
- PVC Insulation
- PVC Jacket
- Copper Conductors
Application:
- For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 300 volts. May be used in NEC Class 1, Division 2 hazardous locations.
Conductors:
- 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.
Insulation:
- Flame-retardant PVC.
Shield:
- Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.
Jacket:
- Sunlight-resistant PVC. A ripcord is applied longitudinally under the jacket to facilitate stripping.
Flame Tests:
- UL 1581 70,000 BTU/hr flame test
- CSA FT4 rated
Color Code:
- ICEA Method 9: black and white for pairs
- ICEA Method 1: black, white and red for triads
- Available upon request: black and red for pairs and black, red and blue for triads
Additional Standards:
- UL Standard 13
- UL Standard 2250
- NEC Type ITC per Articles 501, 502, 503, and 504
- Approved for Class 2 and Class 3 circuits per Article 725 of the NEC