General Cable Multi Conductor 22 AWG 3 Conductor 3.36 mm Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
Select gauge from drop-down menu for prices:
- General Cable Multi Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 24 AWG 2 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 22 AWG 2 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 20 AWG 2 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 18 AWG 2 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 22 AWG 3 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 20 AWG 3 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 20 AWG 3 Conductor 5.41 mm Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 18 AWG 3 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 22 AWG 4 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 20 AWG 4 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 16 AWG 2 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 14 AWG 2 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 12 AWG 2 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 16 AWG 3 Conductor Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 20 AWG 2 Conductor UL Style 2464 Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 22 AWG 2 Conductor Solid Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
- General Cable Multi Conductor 22 AWG 2 Conductor 3.48 mm Foil Shield® Wire NEC Type CL2 and CM (UL) c(UL) CMH
Conductor: 24 thru 12 AWG fully annealed solid or stranded tinned copper per ASTM B33
Insulation:
• Premium-grade, coIor-coded polyethylene
• Premium-grade, coIor-coded polypropylene
• Color code: See charts below
Shield:
• 100% Flexfoil® aluminum/polyester, 25% overlap, foil facing out
• Stranded tinned copper drain wire
Jacket:
• PVC, gray
• Temperature range: -20°C to +75°C
Applications:
• Recording studios and sound stages
• Broadcast and sound systems
• Computers
• Industrial equipment control
• Suggested voltage rating: 300 or 600 volts
Compliances:
• UL Style 2092 (UL: 60°C, 300 V)
• UL Style 2093 (UL: 60°C, 300 V)
• UL Style 2094 (UL: 60°C, 300 V)
• UL Style 2106 (UL: 60°C, 600 V)
• UL Style 2107 (UL: 60°C, 600 V)
• UL Style 2464 (UL: 80°C, 300 V)
• NEC Article 725 Type CL2 (UL: 75°C)
• NEC Article 800 Type CM (UL: 75°C)
• RoHS Compliant Directive 2011/65/EU
• Designed to meet UL 70,000 BTU Vertical Tray Flame Test
• CSA CMH (CSA: 60°C)
• Passes CSA CMH Flame Test
• CE: Low Voltage Directive (LVD) 2006/95/EC
Packaging: Please contact Customer Service for packaging and color options
technical specifications: | |
awg size
|
22 |
no. of cond. | 3 |
cond. strand | 7/30 |
nom. insulation thickness(inches) | 0.008 |
nom. insulation thickness(mm) | 0.20 |
nom. jacket thickness(inches) | 0.020 |
nom. jacket thickness(mm) | 0.51 |
nominal o.d.(inches) | 0.144 |
nominal o.d.(mm) | 3.36 |
nom. cap.*** pf/ft(a) | 25.0 |
nom. cap.*** pf/ft(b)
|
45.0 |
catalog number | C2517A |