Prysmian and Draka Cable 16 AWG 2 Pairs Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394053

Prysmian and Draka Cable 16 AWG 2 Pairs Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394053

Prysmian and Draka Cable 16 AWG 2 Pairs Low Voltage AIRGUARD 600 Volt (IS/OS) Instrumentation Cable 394053

Prysmian’s Low Voltage AIRGUARD™ Instrumenation Cables are primarily designed for applications in the harsh environments found in the heavy industrial and offshore markets. Its rugged polymeric Airbag™ armor and chemical barrier protection package makes it the ideal cable choice for tough harsh environmental conditions. AIRGUARD™ provides the solution to the deficiencies often encountered with MC-HL cables including armor breakage encountered during installation and in applications requiring recurring bending after installation, as well as poor performance in areas of high vibration (e.g. motor connections). It also provides a safer and lower installed cost alternative to MC-HL cables due to faster, “No Knife/ No Saw” cable preparation, and substantially reduced cost of cable glands.

Conductor: Class B stranded bare, soft drawn copper circuit conductors

Insulation: Heat and moisture resistant cross-linked polyethylene (XLPE) meeting the requirements of UL-44 for Type XHHW-2 conductors.

Fillers: Flame resistant non-hygroscopic fillers (as needed)

Drain Wires: Class B stranded bare, soft drawn tinned copper drain wire.

Assembly: An aluminum/ polyester tape with drain wire,100% coverage, is applied over the twisted pairs or triads and the cabled core. Single pair or traid constructions have only the overall shield and drain wire.

Polymeric Armor/Enviromental Barrier: Foamed polymeric AIRBAG™ layer affords superior mechanical & environmental protection of the cable core

Outer Sheath: Heat, moisture, hydrocarbon, and sunlight resistant thermoplastic

Installation
• In Cable Tray Conduit
• Direct Buried Underground Duct
• Isolated in Air Wet Locations
• Dry Locations Industrial
• With Messenger

Specifications:
• ASTM B3 & ASTM B8 Class B Soft Drawn ConcentricLay Stranded Bare Copper Conductors
• ICEA S-82-552 (NEMA WC55) Instrumentation Cable Rating
• UL 44 (XHHW-2) 600V  XHHW-2 Multiple Conductors Direct Buried Sunlight Resistant Oil Resistant
• iEEE 1202/FT-4 Flame Retardant
• UL 1277  NEC Article 336.10(7) TC-ER Exposed Run Rating
• UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1 Hazardous Locations
• NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1 Hazardous Locations
• CSA 22.2 No. 03 -40°C / -35°C Cold Bend/Cold 

Technical Specifications
Number and Circuit Conductor Size 2/PR#16 AWG
Insulation Thickness (Mils) 30
Conductor Diameter (Inches) 0.059
Nominal Overall Insulation (OD) (Inches) 0.123
Nominal Overall Cable (OD) (Inches) 0.770
Nominal Cable Weight (lbs/Mft) 311
Minimum Bending Radius (Inches) 9.3
‡Ampacity (Amps) (‡90°c) 10.0
Gland, Explosion Proof, Class 1 Division 1,Barrier Type 424BT04
Prysmian and Darka Part Number 394053