Prysmian and Draka Cable 3 Cores 50 Cross-section core BFCU 0.6/1kV Power, Fire Resistant and Halogen free Cable 840298

Prysmian and Draka Cable 3 Cores 50 Cross-section core BFCU 0.6/1kV Power, Fire Resistant and Halogen free Cable 840298

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable 3 Cores 50 Cross-section core BFCU 0.6/1kV Power, Fire Resistant and Halogen free Cable 840298
Prysmian and Draka Cable 3 Cores 50 Cross-section core BFCU 0.6/1kV Power, Fire Resistant and Halogen free Cable 840298

Conductor: Tinned stranded circular copper, BS 6360, class 2

Insulation: Mica glass tape / EP-rubber, GP4 to BS 7655: section 1.2

Lay up / Shielding: Cores laid up in concentric layers

Inner covering: Flame retardant and halogen-free thermoplastic EP-rubber based compound

Tape over inner covering: PET tape + rubberized Polyamide tape

Armour/screen: Galvanized steel wire braid

Tape over armour/screen: PET + tape rubberised Polyamide tape

Outer sheath: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking text: "metre mark" "year" "DRAKA" "BFCU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS7917" "IEC60331-21" "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour: Black

Operating temperature: 90°C

Operating Voltage: 0.6/1kV

Standards applied:
• BS7917/BS6883/UKOOA - Design
• BS6360 class 2 - Conductor
• BS7655 section 1.2 - Insulation
• BS7655 section 2.6 - Sheath
• IEC 60332-1 & 3-22 - Flame Retardant
• IEC60331-21 - Fire Resistant
• IEC60754-1,2 - Halogen Free
• IEC 61034-1,2 - Low Smoke

Core identification: All cores are offwhite with black numbers No 1,2,3....

Description:
• BFCU 0.6/1kV 2X 1.5mm2
• BFCU 0.6/1kV 2X 2.5mm2
• BFCU 0.6/1kV 2X 4mm2
• BFCU 0.6/1kV 2X 6mm2
• BFCU 0.6/1kV 2X 10mm2
• BFCU 0.6/1kV 2X 16mm2
• BFCU 0.6/1kV 2X 35mm2
• BFCU 0.6/1kV 3X 1.5mm2
• BFCU 0.6/1kV 3X 2.5mm2
• BFCU 0.6/1kV 3X 4mm2
• BFCU 0.6/1kV 3X 6mm2
• BFCU 0.6/1kV 3X 10mm2
• BFCU 0.6/1kV 3X 16mm2
• BFCU 0.6/1kV 3X 25mm2
• BFCU 0.6/1kV 3X 35mm2
• BFCU 0.6/1kV 3X 50mm2
• BFCU 0.6/1kV 3X 70mm2
• BFCU 0.6/1kV 3X 95mm2
• BFCU 0.6/1kV 4X 1.5mm2
• BFCU 0.6/1kV 4X 2.5mm2
• BFCU 0.6/1kV 4X 4mm2
• BFCU 0.6/1kV 4X 6mm2
• BFCU 0.6/1kV 4X 35mm2
• BFCU 0.6/1kV 4X 70mm2
• BFCU 0.6/1kV 7X 1.5mm2
• BFCU 0.6/1kV 7X 2.5mm2
• BFCU 0.6/1kV 12X 1.5mm2
• BFCU 0.6/1kV 12X 2.5mm2
• BFCU 0.6/1kV 19X 2.5mm2
• BFCU 0.6/1kV 27X 2.5mm2

Sheath Colour: BLACK

Design standard:
• BS 7917 : 1999
• BS 6883 : 1991

Application:
• Armoured cable for fixed installation for power, control or lighting in both EX and safe areas, emergency and critical systems where there is a requirement for fire reistant cables.
• Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

technical specification:
number of cores 3
cross-section core, mm2 50
conductor diameter, mm 9
insulation thickness, mm 1.4
thickness inner sheath, mm 1.8
approx. diameter inner sheath, mm 30.5
diameter braid wire, mm 0.45
thickness outer sheath, mm 2
approx. overall diameter, mm 36.5
weight of cable approx. (kg/km) 2890
copper content approx. (kg/km) 1293
max. conductor resistance at 20°c, ohm/km 0.391
max. conductor resistance at 90°c, ohm/km 0.499
reactance at 50hz, ohm/km 0.078
reactance at 60hz, ohm/km 0.093
current rating iec 60092-352 table b.4, ampere 137
short circuit rating 1 second, ampere 7000
ukooa code yd350
prysmian and draka cable part number 840298

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question