Conductor: The conductor is stranded in accordance with AAR specification 591. The wires are soft, annealed copper with a continuous coating of tin (98.0% conductivity) in accordance with ASTM B33.
Insulation: Ethylene propylene rubber (EPR) to comply with AAR specification 591. Insulation is heat, oil and moisture-resistant and rated for 75°C wet and 90°C dry continuous operating conditions. An opaque polyester tape or other suitable separator is used over the conductor.
Jacket: Chlorosulfonated polyethylene (CSPE) to comply with AAR specification 591. The jacket is bonded to the EPR insulation.
Surface marking: The jacket surface shall be printed or indented with: DRAKA (sequential footage every two feet).
Applications: These are single conductor 600/2000 volt cables designed for use in powering diesel/electric traction wheels. They consist of an ethylene propylene rubber (EPR) insulated conductor and a chlorosulfonated polyethylene (CSPE) jacket. They meet AAR 591, are highly heat, oil and moisture-resistant, extremely flexible, and can sustain 75°C wet/90°C dry operating temperatures.
Ratings: - Meets AAR 591 specifications
technical specification: | |
conductor size | 313 kcmil |
stranding | 775/24 |
average insulation thickness in (mm) | .094 (2.4) |
average jacket thickness in (mm) | .047 (1.2) |
minimum bend radius in (mm) | 5.15 (131) |
approximate cable o.d in (mm) | 1.030 (26.2) |
cable weight lbs/mft (kg/km) | 1285 (1915) |
prysmian and draka cable part number | d20313 |