Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 8 Power - 10 Bond Wire
Select gauge from drop-down menu for prices:
Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 8 Power - 10 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 12 Power - 14 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 10 Power - 12 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 6 Power - 8 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 4 Power - 8 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 2 Power - 6 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 1 Power - 6 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 1/0 Power - 6 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 2/0 Power - 6 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 14 AWG - 4/0 Power - 4 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 12 AWG - 10 Power - 12 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 12 AWG - 8 Power - 10 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 12 AWG - 6 Power - 8 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 12 AWG - 4 Power - 8 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 12 AWG - 2 Power - 6 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 12 AWG - 1 Power - 6 Bond Wire
- Teck 90 Armoured Power Control Composite 3 Power & 3 Control Conductors 600V XLPE/PVC/AIA/PVC - 12 AWG - 1/0 Power - 6 Bond Wire
Technical Specifications: | |
Catalog Number | 05030-03-010 |
AWG Control | 14 |
AWG Power |
8 |
AWG Bond Wire | 10 |
Insulation Thickness (in.) | 0.450 |
Approximate Diameter (Over) Inner Jacket (in.) | 0.690 |
Approximate Diameter (Over) Armour (in.) | 0.950 |
Approximate Diameter (Over) Outer Jacket (in.) | 1.000 |
Copper Content LB/ MFT | 208 |
Copper Content KG/ KM | 310 |
Net Weight
w/ Armour LB/
MFT |
541 |
Net Weight w/ Armour KG/ KM | 805 |
Amp. (30°C Ambient) | 55 |
Recommended Connector TMC2 | 3/3A |
Recommended Connector TMC2X | 3/3A |
Specifications:
- Teck 90 Armoured Power
- Control Composite 3 Power &
- 3 Control Conductors 600V
- XLPE/PVC/AIA/PVC
- CSA FT1 & FT4
- CSA C22.2 No. 131 & 174
- IEEE 383 & 1202 (70,000 BTU/hr) Flame Test
- ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
CONSTRUCTION:
- Conductor: Bare copper Class B compressed stranded
- Insulation: Cross-Linked Polyethylene (XLPE) Type RW90
- Ground (Bonding) Conductor: Uninsulated stranded bare copper conductor
- Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
- Armour: Aluminum Interlocked Armour (AIA)
- Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
- Options: Galvanized Steel Interlocked Armour (GSIA) Other coloured outer jacket and constructions available upon request