General Cable TECK90® 3/0 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
Select gauge from drop-down menu for prices:
- General Cable Teck90® Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
- General Cable TECK90® 12 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
- General Cable TECK90® 10 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
- General Cable TECK90® 8 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
- General Cable TECK90® 6 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
- General Cable TECK90® 4 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
- General Cable TECK90® 2 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
- General Cable TECK90® 1 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
- General Cable TECK90® 1/0 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
- General Cable TECK90® 2/0 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
- General Cable TECK90® 4/0 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
Conductor:
• 12 AWG thru 8 AWG bare copper Class B compressed concentric round to ASTM B8
• 6 AWG thru 4/0 AWG bare copper compact Class B strand
Insulation:
• Cross-linked Polyethylene (XLPE), Type RW90
• Color-coded: 14 AWG to 2 AWG—black, red and blue; 1 AWG to 4/0 AWG—printed numbers
Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor
Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
Armor: Aluminum Interlocked Armor (AIA)
Overall Jacket: Lead-free, ACID-FLAME-CHECK ??® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
Options: Galvanized Steel Interlocked Armor (GSIA)
Applications:
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)
• For wiring in all hazardous locations when used with certified HL cable glands
Features:
• Rated at 90?C wet or dry
• Excellent crush, oil and chemical resistance
• Provides long service life
• Meets cold bend and impact tests at -40?C
Compliances:
Industry Compliances: CSA Standard C22.2 No. 131 and No. 174
Flame Test Compliances:
• CSA FT1 and FT4
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
• Hazardous Location Rating: HL
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant
Packaging:
• For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
• For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing
technical speicfication | |
cond. size(AWG/kcmil) | 3/0 |
no. of cond. | 3 |
ground wire size (AWG) | 4 |
min. avg. ins. thickness(inches) | .055 |
min. avg. ins. thickness(mm) | 1.40 |
nominal diameter (over)(insulation in inches) | 0.58 |
nominal diameter (over)(insulation in mm) | 17.1 |
nominal diameter (over)(armor in inches) | 1.68 |
nominal diameter (over)(armor in mm) | 42.5 |
nominal diameter (over)(cable in inches) | 1.82 |
nominal diameter (over)(cable in mm) | 46.1 |
copper weight(lbs/1000ft) | 1753 |
copper weight(kg/km) | 2609 |
net weight w/armor(lbs/1000ft in al) | 2592 |
net weight w/armor(lbs/1000ft in steel) | 3087 |
net weight w/armor(kg/km in al) | 3857 |
net weight w/armor(kg/km in steel) | 5740 |
ampacity** power cond. (30?c ambient) | 225 |
catalog number | 11288.215300* |