General Cable Type MC XLPE 600V Armored Composite 3x#2 Power AWG and 3x#14 Control AWG Without Ground UL Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

General Cable Type MC XLPE 600V Armored Composite 3x#2 Power AWG and 3x#14 Control AWG Without Ground UL Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

Select gauge from drop-down menu for prices:

General Cable Type MC XLPE 600V Armored Composite 3x#2 Power AWG and 3x#14 Control AWG Without Ground UL Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

Product Details

Conductor:
• Bare annealed copper per ASTM B3 
• Sizes 10 AWG and smaller are Class B compressed stranding per ASTM B8 
• Sizes 8 AWG and larger are compact stranding per ASTM B496

Insulation:
• Cross-Linked Polyethylene (XLPE) insulation per ICEA S-95-658 and UL 44, Listed XHHW-2 
• Power conductors sizes 6 AWG and smaller are color-coded per ICEA Method 1, Table E2 
• Power conductors sizes 4 AWG and larger are black with printed numbers per ICEA Method 4 
• Control conductors are color-coded black, red, blue and yellow

Cable Assembly:
• Insulated conductors are cabled together with non-hygroscopic fillers when required 
• A binder tape, when required, is applied over the cabled core

CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1569 
• CCW armor conductivity meets the grounding requirements of NEC Article 250

Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black 
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C

Applications:
• CCW armored Composite Power and Control cables offer an economical, rugged and reliable alternative to  labor-intensive cable in conduit wiring methods 
• For use in Class I and II, Division 2; Class III, Divisions 1 and 2; and Class I, Zone 2 hazardous locations  per NEC Articles 501, 502, 503 and 505 
• For use as services, feeders and branch circuits for power, lighting, control, and signal circuits in accordance  with NEC Articles 330 and 725
• Installed indoors or outdoors, wet or dry locations, directly buried, embedded in concrete, in a raceway, as  aerial cable on a messenger, in cable trays, or as exposed runs secured to supports in accordance with NEC  Article 330 
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American  Petroleum Institute

Features:
• CCW armor provides an impervious barrier to moisture, gas and liquids 
• CCW armor provides EMI shielding performance 
• Factory assembled and tested cable for use as an alternative to cable in conduit wiring systems  
• Meets cold impact at -40°C 
• 90°C continuous operating temperature, wet or dry 
• 130°C emergency rating 
• 250°C short circuit rating

Specifications:
Design Adherence: 
• ICEA S-95-658/WC 70 Standard for Non-Shielded Power Cable, 2 kV or Less 
• UL 44 Rubber Insulated Wires and Cables 
• UL 1569 Metal Clad Cables 
• UL 1309 Marine Shipboard Cable

Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr) 
• IEEE 383 (70,000 BTU/hr) 
• CSA FT4 
• IEEE 1202 (70,000 BTU/hr) 
• UL 1581 (70,000 BTU/hr) 
• IEC 60332-3 Cat. A

Compliances:
• UL Type MC, XHHW-2, SUN RES, CT USE, DIR BUR, -40°C, UL File # E69797 
• UL Listed Marine Shipboard, UL File # E85994 
• American Bureau of Shipping (ABS) Listed for CWCMC 
• RoHS Compliant

techinal specification:
power cond. size (awg) 3x#2 (7/W) (33.6 mm²)
power insulationthickness(mils) 45
power insulation thickness(mm) 1.14
control cond. size (awg) 3x#14 (7/W) (2.08 mm²)
control insulation thickness(mils) 30
control insulation thickness(mm) 0.76
nominal core o.d.(inches) 0.81
nominal core o.d.(mm) 20.6
nominal armor o.d.(inches) 1.06
nominal armor o.d.(mm) 26.9
jacket thickness(mils) 50
jacket thickness(mm) 1.27
nominal overall o.d.(inches) 1.17
nominal overall o.d.(mm) 29.7
crosssectional area¹ (sq. in.) 1.09
approximate net weight(lbs/1000 ft) 995
approximate net weight(kg/1000 m) 1,481
90°c ampacity@ 30°cambient² 130
catalog number 9650.023143000

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question