Belden 3612 Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable Category 6 Cable
- Belden 7852A Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable
- Belden 4813 Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable
- Belden 7851A Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable
- Belden 4812 Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable
- Belden 3633 Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest PVC Jacket Cable
- Belden 3613 Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest PVC Jacket Cable
- Belden 3632 Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable
- Belden 1874A Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable
- Belden 2413 Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable
- Belden 1872A Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable
- Belden 2412 Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable
- Belden 2413F Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair ScTP Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable
- Belden 2412F Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair ScTP Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable
- Belden 6663U6 Cable 23 AWG 4 Pairs Category 6 Compliant for Video Sound and Security Application Multi Conductor Solid BC Flamarrest Jacket Cable
- Belden 5663U6 Cable 23 AWG 4 Pairs Category 6 Compliant for Video Sound and Security Application Multi Conductor Solid BC PVC Jacket Cable
- Belden 1352A Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair ScTP Enhanced Multi Conductor Solid BC Flamearrest Jacket Cable
- Belden 1351A Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair ScTP Enhanced Multi Conductor Solid BC PVC Jacket Cable
- Belden 1875GB Cable 24 AWG 4 Pairs Category 6 Bonded-Pair Patch Enhanced Multi Conductor Stranding 7x32 TC PVC Jacket Cable
- Belden 7883A Cable 24 AWG 4 Pairs Category 6 NonBonded-Pair Patch Enhanced Multi Conductor Solid BC PVC Jacket Cable
- Belden OSP6U Cable 24 AWG 4 Pairs Category 6 Outside Plant Multi Conductor Solid Bare Copper PE Jacket Cable
- Belden 2143A Cable 23 AWG 4 Pairs Category 6 Indoor/Outdoor OSP and CM-LS Multi Conductor Solid BC Flame Retardant Polyolefin Jacket Cable
- Belden 2146A Cable 23 AWG 4 Pairs Category 6 Indoor/Outdoor CMR/CMX Outdoor Multi Conductor Solid BC UV Resistant PVC Jacket Cable
- Belden 2149A Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair ScTP Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable
Description:
• CAT6+ (400MHz), 4-Pair, U/UTP-Unshielded, Riser-CMR, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, Polyolefin Insulation, Patented X-Spline, Ripcord, PVC jacket.
Insulation:
• Material: Polyolefin
Outer Jacket:
• Material: PVC
• Nom. Wall Thickness (in.): 0.017
• Nom. Diameter (in.): 0.231
• Outer Jacket Ripcord: Yes
Usage (Overall):
Applications:
• Premise Horizontal Cable, Gigabit Ethernet, POE, POE+,100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments.
Mechanical Characteristics (Overall):
• Storage Temperature Range: -30°C To +75°C
• Installation Temperature Range: +5°C To +50°C
• Operating Temperature Range: 0°C To +75°C
• UL Temperature Range: 75°C
• Bulk Cable Weight: 28 lbs/1000 ft.
• Max. Recommended Pulling Tension: 45 lbs.
• Min. Bend Radius/Minor Axis: 0.750 in.
• Min. Bend/Installation: 2.250 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR
• CEC/C(UL) Specification: CMR
• EU Directive 2011/65/EU (ROHS II): Yes
• Other Standards: ISO/IEC 11801 ed 2.1 (2008) Class E
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/03/2009
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6 - TIA 568.C.2
Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 15.5
• Maximum Capacitance Unbalance (pF/100 m): 330
• Nominal Velocity of Propagation: VP (%): 70.000
• Maximum Delay (ns/100 m): 537.600 @ 100MHz
• Typical Delay Skew (ns/ft): 35.000
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 7.700
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3.000
Flame Test:
• UL Flame Test: UL1666 Vertical Riser
• C(UL) Flame Test: FT4
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: No
• Suitability - Aerial: No
• Suitability - Burial: No
• Sunlight Resistance: No
Plenum/Non-Plenum:
• Plenum(Y/N): No
• Plenum Number: 3613
technical specification: | |
awg | 23 |
# pairs | 4 |
stranding | solid |
no. of conductors | 8 |
conductor material | bare copper |
outer shield - type | - |
outer shield - material | unshielded |
overall cable - nominal diameter (in.) | 0.231 |
belden cable part number | 3612 |