Belden 2146A Cable 23 AWG 4 Pairs Category 6 Indoor/Outdoor CMR/CMX Outdoor Multi Conductor Solid BC UV Resistant PVC Jacket Cable

Belden 2146A Cable 23 AWG 4 Pairs Category 6 Indoor/Outdoor CMR/CMX Outdoor Multi Conductor Solid BC UV Resistant PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 2146A Cable 23 AWG 4 Pairs Category 6 Indoor/Outdoor CMR/CMX Outdoor Multi Conductor Solid BC UV Resistant PVC Jacket Cable

Regular price $0.77 $0.51 Sale /per Foot

Belden 2146A Cable 23 AWG 4 Pairs Category 6 Indoor/Outdoor CMR/CMX Outdoor Multi Conductor Solid BC UV Resistant PVC Jacket Cable

Description:
• CAT6 (350MHz), 4-Pair, U/UTP-Unshielded, Riser-CMR, CMX Outdoor, Premise Horizontal Cable, 23 AWG solid bare copper conductors, non-plenum, Polyolefin insulation, Film separator, Ripcord, UV Resistant PVC Jacket.

Insulation:
• Material: PO - Polyolefin

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Diameter (in.): 0.250
• Outer Jacket Ripcord: Yes

Outer Jacket over Armor:
• Outer Jacket Material over Armor (y/n): Yes - CMX - Outdoor

Usage (Overall):
Applications:
• Premise Horizontal Cable, Outdoor, Riser, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM.

Mechanical Characteristics (Overall):
• Storage Temperature Range: -40°C To +75°C
• Installation Temperature Range: -20°C To +75°C
• Operating Temperature Range: -40°C To +75°C
• UL Temperature Rating: 75°C (UL AWM Style 444)
• Bulk Cable Weight: 30 lbs/1000 ft.
• Max. Recommended Pulling Tension: 40 lbs.
• Min. Bend Radius/Minor Axis: 0.750 in.
• Min. Bend/Installation: 2.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, CMR, CMX-Outdoor
• CEC/C(UL) Specification: CMR
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6 - TIA 568.C.2
• ANSI Specification: ANSI/NEMA WC-66, ANSI/ICEA S-90-661, ANSI/UL 444. ANSI/TIA 568-C.2
• Other Specification: Third party verified to Category 6

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 17.000
• Maximum Capacitance Unbalance (pF/100 m): 330
• Nominal Velocity of Propagation: VP (%): 70
• Maximum Delay (ns/100 m): 537 @ 100MHz
• Max. Delay Skew (ns/100 m): 35.000
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 7.800
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3.000

Flame Test:
• UL Flame Test: UL1666 Vertical Riser
• C(UL) Flame Test: FT4
• CSA Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes - CMX - Outdoor
• Suitability - Aerial: Yes - When supported by messenger wire
• Suitability - Buiral: No
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 23
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type -
outer shield - material unshielded
overall cable - nominal diameter (in.) 0.250
belden cable part number 2146A

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question