Belden 2413 Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Belden 2413 Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Select gauge from drop-down menu for prices:

Belden 2413 Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Regular price $870.00 $585.00 Sale /per Foot

Belden 2413 Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Description:
• CAT6+ (350 MHz), 4-Pair, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, Dual FRPO/FEP Insulation, Tape Separator, Ripcord, Flamarrest® Jacket.

Insulation:
• Material: FRPO/FEP - Flame Retardant Polyolefin/Fluorinated Ethylene Propylene

Outer Jacket:
• Trade Name: Flamarrest
• Material: LS PVC - Low Smoke Polyvinyl Chloride
• Nom. Diameter (in.): 0.224
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Premise Horizontal Cable, Gigabit Ethernet, POE, POE+,100BaseTX, 100BaseVG ANYLAN, 155 ATM, 622 ATM, 250MHz Category 6, PoE, PoE Plus.

Mechanical Characteristics (Overall):
• Storage Temperature Range: -20°C To +75°C
• Installation Temperature Range: +5°C To +50°C
• Operating Temperature Range: -20°C To +75°C
• Bulk Cable Weight: 27 lbs/1000 ft.
• Max. Recommended Pulling Tension: 40 lbs.
• Min. Bend Radius/Minor Axis: 0.750 in.
• Min. Bend/Installation: 2.250 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• NEC Articles: NFPA 70 Article 800
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/13/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6 - TIA 568.C.2
• ANSI Specification: ANSI/NEMA WC-66, ANSI/ICEA S-90-661, ANSI/UL 444
• Other Specification: C(UL)US CMP 90C OR (UL) CMP-LP (0.5A) OR CL3P-LP (0.5A)

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 15
• Maximum Capacitance Unbalance (pF/100 m): 330
• Nominal Velocity of Propagation: VP (%): 72
• Maximum Delay (ns/100 m): 537 @ 100MHz
• Max. Delay Skew (ns/100 m): 35.000
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 7.800
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3.000

Flame Test:
• UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6)
• C(UL) Flame Test: FT6
• CSA Flame Test: FT6

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: No

Plenum/Non-Plenum:
• Plenum(Y/N): Yes
• Non-Plenum Number: 2412

technical specification:
awg 23
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type -
outer shield - material unshielded
overall cable - nominal diameter (in.) 0.224
belden cable part number 2413

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question