Belden 2149A Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair ScTP Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable

Belden 2149A Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair ScTP Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 2149A Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair ScTP Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable
Belden 2149A Cable 23 AWG 4 Pairs Category 6 NonBonded-Pair ScTP Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable

Description:
• CAT6+ (350MHz), 4-Pair, F/UTP-Foil Shielded, Riser-CMR-CMX Outdoor, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, Polyolefin Insulation, Patented X-Spline, Overall Beldfoil Shield, PVC Jacket.

Insulation:
• Material: PO - Polyolefin

Outer Jacket Drain Wire AWG:
• AWG: 24
• Stranding: Solid
• Conductor Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Diameter (in.): 0.293
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Networking Horizontal Cable, HDBaseT, 1000Base-T (Gigabit Ethernet), 100Base-T (Fast Ethernet), 10Base-T (Ethernet), 100BaseVG, ANYLAN, 155ATM, 622ATM, ANSI.X3.263 FDDI TP-PMD, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422, Noisy Environments, 250 MHz Category 6, Outdoor.

Mechanical Characteristics (Overall):
• Storage Temperature Range: -40°C To +75°C
• Installation Temperature Range: -20°C To +75°C
• Operating Temperature Range: -40°C To +75°C
• Bulk Cable Weight: 41 lbs/1000 ft.
• Max. Recommended Pulling Tension: 25 lbs.
• Min. Bend Radius/Minor Axis: 1.200 in.
• Min. Bend/Installation: 2.900 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR, CMX-Outdoor, UL444
• CEC/C(UL) Specification: CMG
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 12/08/2011
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6 - TIA 568.C.2

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 14.000
• Maximum Capacitance Unbalance (pF/ft): 66.000
• Nominal Velocity of Propagation: VP (%): 68.000
• Maximum Delay (ns/100 m): 537.000 @ 100MHz
• Max. Delay Skew (ns/100 m): 30.000
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 8.200
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3.000

Flame Test:
• UL Flame Test: UL1666 Vertical Riser
• C(UL) Flame Test: FT4
• CSA Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes - CMX - Outdoor

Plenum/Non-Plenum:
• Plenum(Y/N): No
• Plenum Number: 2413F
• Non-Plenum Number: 2412F

technical specification:
awg 23
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal diameter (in.) -
belden cable part number 2149A