Belden 9614 Cable 24 AWG 9 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable

Belden 9614 Cable 24 AWG 9 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 9614 Cable 24 AWG 9 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable

Regular price $9.86 $7.19 Sale /per Foot

Belden 9614 Cable 24 AWG 9 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable

Description:
• 24 AWG stranded (7x32) tinned copper conductors, S-R PVC insulation, overall Beldfoil® (100% coverage), TC braid shield (65% coverage), PVC jacket

Insulation:
• Material: S-R PVC - Semi-Rigid Polyvinyl Chloride
• Wall Thickness (mm): 0.2794

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.889

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 40 lbs/1000 ft.
• Max. Recommended Pulling Tension: 71 lbs.
• Min. Bend Radius/Minor Axis: 2.750 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 30
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 55
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 25
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 7.5
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.5 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 24
# conductors 9
stranding 7x32
no. of conductors 9
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 6.477
belden cable part number 9614

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question