Belden 9641 Cable 26 and 24 AWG Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable Computer Cable for EIA RS-232 Applications Multi Conductor Overall Foil/Braid Shield Cable
- Belden 9637 Cable 28 AWG 25 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9791 Cable 28 AWG 6 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9608 Cable 24 AWG 3 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9609 Cable 24 AWG 4 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9610 Cable 24 AWG 5 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9611 Cable 24 AWG 6 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9612 Cable 24 AWG 7 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9613 Cable 24 AWG 8 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9614 Cable 24 AWG 9 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9615 Cable 24 AWG 10 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9616 Cable 24 AWG 15 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9617 Cable 24 AWG 25 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9618 Cable 24 AWG 37 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9619 Cable 24 AWG 50 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9939 Cable 22 AWG 3 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9940 Cable 22 AWG 4 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9941 Cable 22 AWG 5 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9942 Cable 22 AWG 6 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9943 Cable 22 AWG 7 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9944 Cable 22 AWG 8 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9945 Cable 22 AWG 9 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9946 Cable 22 AWG 10 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9947 Cable 22 AWG 15 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9948 Cable 22 AWG 25 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9949 Cable 22 AWG 37 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
- Belden 9950 Cable 22 AWG 50 Conductors Computer Cable for EIA RS-232 Applications Overall Foil/Braid Shield PVC Jacket Cable
Description:
• 26 AWG stranded (7x34)and 24 AWG stranded (7x32) tinned copper conductors, semi-rigid PVC insulation, overall Beldfoil (100% Coverage) plus inned copper braid shield (90% Coverage), drain wire, PVC jacket.
Insulation:
• Material: S-R PVC - Semi-Rigid Polyvinyl Chloride
Outer Shield Drain Wire AWG:
• AWG: 26
• Stranding: 7x34
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
Overall Cable:
• Separator Material: Polyester
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 71 lbs/1000 ft.
• Max. Recommended Pulling Tension: 140 lbs.
• Min. Bend Radius/Minor Axis: 3.500 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• NEC/(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• CSA Specification: AWM I A
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: 488
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 23.3 (24 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 37.3 (26 AWG)
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 2.6
• Max. Operating Voltage - UL: 300 V RMS (UL AWM Style 2464)
• Max. Recommended Current: 0.6 Amps/Conductor @ 25°C (26 AWG)
• Max. Recommended Current: 1.1 Amps/Conductor @ 25°C (24 AWG)
Flame Test:
• C(UL) Flame Test: FT4
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 26 and 24 |
# conductors | 10 and 1 |
stranding | 7x34 and 7x32 |
no. of conductors | 23 |
conductor material | tinned copper |
outer shield - type | tape/braid |
outer shield - material | tinned copper |
overall cable- nominal dia. (mm) | 8.89 |
belden cable part number | 9641 |