Conductors: 1/0 AWG thru 1000 kcmil bare compact copper, Class B stranding per ASTM B496 

Insulation:
• Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 3, Table E-2

Ground: Annealed bare copper Class B stranding per ASTM B8

Armor: Aluminum Interlocked Armor (AIA)

Jacket: Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Options: Galvanized Steel Interlocked Armor (GSIA)

Applications:
• Ideally suited for use in a broad range of commercial, industrial and utility applications, where maximum performance is demanded, ease of installation desired and fire resistance is critical
• Permitted for use per NEC Article 334 - Class I, Division 2 - Class II, Division 2 - Class III, Divisions 1 and 2
• Installed in both exposed or concealed work, wet or dry locations, indoors or outdoors and cable trays

Features:
• Rated at 90?C wet or dry
• Provides excellent oil and chemical resistance
• Excellent crush resistance
• Provides a long service life
• Cost-effective alternative to installations in conduit
• Meets cold bend test at -40?C

Compliances:
Industry Compliances:
• UL 1569
• UL 44
• ICEA S-95-658/NEMA WC70
• UL Type MC-600 volts, UL File # E90496
• NEC Type XHHW-2 conductors

Flame Test Compliances:
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)

Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant

Packaging: For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

technical specification:
cond. size (awg) 250
no. of cond. 3
grnd. wire size (awg) 3x4
minimum insulation thickness(inches) 0.065
minimum insulation thickness(mm) 1.65
nom. dia. (over) armor(inches) 1.72
nom. dia. (over) armor(mm) 43.6
nominal jacket thickness(inches) 0.060
nominal jacket thickness(mm) 1.52
nominal cable o.d.(inches) 1.85
nominal cableo.d.(mm) 46.9
copper weight(lbs/1000ft) 2644
copper weight(kg/km) 3935
net weight(lbs/1000ft) 3418
net weight(kg/km) 5086
catalog number 11298.516000*