General Cable Duralox® XLPE AIA PVC 350MCM 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
Select gauge from drop-down menu for prices:
- General Cable Duralox® XLPE AIA PVC (1/0 AWG-1000MCM) Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 1/0 AWG 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 2/0 AWG 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 3/0 AWG 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 4/0 AWG 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 250MCM 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 500MCM 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 750MCM 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 1000MCM 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
Product Details
Conductors: 1/0 AWG thru 1000 kcmil bare compact copper, Class B stranding per ASTM B496
Insulation:
• Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 3, Table E-2
Ground: Annealed bare copper Class B stranding per ASTM B8
Armor: Aluminum Interlocked Armor (AIA)
Jacket: Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
Options: Galvanized Steel Interlocked Armor (GSIA)
Applications:
• Ideally suited for use in a broad range of commercial, industrial and utility applications, where maximum performance is demanded, ease of installation desired and fire resistance is critical
• Permitted for use per NEC Article 334 - Class I, Division 2 - Class II, Division 2 - Class III, Divisions 1 and 2
• Installed in both exposed or concealed work, wet or dry locations, indoors or outdoors and cable trays
Features:
• Rated at 90?C wet or dry
• Provides excellent oil and chemical resistance
• Excellent crush resistance
• Provides a long service life
• Cost-effective alternative to installations in conduit
• Meets cold bend test at -40?C
Compliances:
Industry Compliances:
• UL 1569
• UL 44
• ICEA S-95-658/NEMA WC70
• UL Type MC-600 volts, UL File # E90496
• NEC Type XHHW-2 conductors
Flame Test Compliances:
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant
Packaging: For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing
technical specification: | |
cond. size (awg) | 350 |
no. of cond. | 3 |
grnd. wire size (awg) | 3x2 |
minimum insulation thickness(inches) | 0.065 |
minimum insulation thickness(mm) | 1.65 |
nom. dia. (over) armor(inches) | 1.92 |
nom. dia. (over) armor(mm) | 48.9 |
nominal jacket thickness(inches) | 0.060 |
nominal jacket thickness(mm) | 1.52 |
nominal cable o.d.(inches) | 2.05 |
nominal cableo.d.(mm) | 52.2 |
copper weight(lbs/1000ft) | 3761 |
copper weight(kg/km) | 5597 |
net weight(lbs/1000ft) | 4675 |
net weight(kg/km) | 6957 |
catalog number | 11298.516200* |