Skip to product information
1 of 1

TYPE TC-ER - CONTROL & POWER TRAY CABLE Unshielded XLPE Insulation with Overall CPE Jacket 600 Volts 90°C Wet/Dry - 18 AWG - 3 Conductors

TYPE TC-ER - CONTROL & POWER TRAY CABLE Unshielded XLPE Insulation with Overall CPE Jacket 600 Volts 90°C Wet/Dry - 18 AWG - 3 Conductors

SKU: SKU:  

Select a gauge:
  • TYPE TC-ER - CONTROL & POWER TRAY CABLE Unshielded XLPE Insulation with Overall CPE Jacket 600 Volts 90°C Wet/Dry - 18 AWG - 3 Conductors
Length: FT
Enter footage in the box - Cut to one length. Min 1 ft - Max 10000 ft.
Sold out
Shipping calculated at checkout.
Shipping Available
Free shipping on orders above $1000. *Wires and cables only.
View full details
Product Information

Technical Specifications:
Product Code 51803
Size AWG 18
No. of Conductors
3
Strands 7
XLPE Insulation Thickness (Mils) 30
Approximate O.D. (Inches) .106
OA Jkt. Thick. (MILS)
45
Appr. O.D. (IN) 324
Appr. Weight Lbs./ M Ft 53

Specifications:

  • TYPE TC-ER - CONTROL & POWER TRAY CABLE
  • Unshielded XLPE Insulation with Overall CPE Jacket
  • 18 - 10 AWG • 600 Volts • 90°C Wet/Dry

Description:
ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall fame retardant, sunlight resistant Chlorinated Polyethylene (CPE) jacket.

Application:
Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where fame retardance and moisture/chemical resistance is critical. Intended for control, power, lighting, telemetering, signals and relay or trafc control.

Conductors:
Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.

Insulation: XLPE:
Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.

Cabling:
Conductors are assembled with fllers in the core as needed.

Separator:
Mylar

Overall Jacket:
A black, fame resistant, Chlorinated Polyethylene (CPE) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.

Color Code:
ICEA Method 1 Tables E-1, E-2 & Method 4

Industry Listings and Standards:

  • UL Listed as TC-ER per UL Standard 1277*
  • Rated -40°C to 90°C
  • OSHA Acceptable
  • NEC Articles 392
  • CSA FT4
  • IEEE 1202 70,000 BTU Flame Test
  • ASTM - All Applicable Standards
  • *UL 1277 requires a ground or three conductors to be rated ER