8 THHN THWN-2 Stranded Copper Building Wire
8 THHN THWN-2 Stranded Copper Building Wire
SKU: SKU: NES0140 Download PDF
- 8 THHN THWN-2 Stranded Copper Building Wire
- 8 THHN THWN-2 Stranded Copper Building Wire
- THHN THWN-2 Copper Building Wire
- 10 AWG THHN THWN-2 Solid Copper Building Wire
- 12 AWG THHN THWN-2 Solid Copper Building Wire
- 14 AWG THHN THWN-2 Solid Copper Building Wire
- 14 THHN THWN-2 Stranded Copper Building Wire
- 12 THHN THWN-2 Stranded Copper Building Wire
- 10 THHN THWN-2 Stranded Copper Building Wire
- 6 THHN THWN-2 Stranded Copper Building Wire
- 4 THHN THWN-2 Stranded Copper Building Wire
- 3 THHN THWN-2 Stranded Copper Building Wire
- 2 THHN THWN-2 Stranded Copper Building Wire
- 1 THHN THWN-2 Stranded Copper Building Wire
- 1/0 THHN THWN-2 Stranded Copper Building Wire
- 2/0 THHN THWN-2 Stranded Copper Building Wire
- 3/0 THHN THWN-2 Stranded Copper Building Wire
- 4/0 THHN THWN-2 Stranded Copper Building Wire
- 250 MCM THHN THWN-2 Stranded Copper Building Wire
- 300 MCM THHN THWN-2 Stranded Copper Building Wire
- 350 MCM THHN THWN-2 Stranded Copper Building Wire
- 400 MCM THHN THWN-2 Stranded Copper Building Wire
- 500 MCM THHN THWN-2 Stranded Copper Building Wire
- 600 MCM THHN THWN-2 Stranded Copper Building Wire
- 750 MCM THHN THWN-2 Stranded Copper Building Wire
- 1000 MCM THHN THWN-2 Stranded Copper Building Wire
- 250' 10 AWG THHN THWN-2 Solid Copper Building Wire
- 500' 10 AWG THHN THWN-2 Solid Copper Building Wire
- 1000' 10 AWG THHN THWN-2 Solid Copper Building Wire
Shipping Available
Couldn't load pickup availability
Also Known As:
8 thhn, 8 awg thwn 2, 8 awg thhn, 8 stranded thhn, 8 gauge stranded wire, 8 copper wire, 8 awg stranded copper wire, 8 awg Copper wire, 8 awg building cable, 8 awg conduit wire, 8 awg nylon wire, 8 awg construction cable, 8 awg thermoplastic-insulated copper wire, 8 awg THHN-PVC tray cable.
Conductor:
THHN THWN-2 conductors are constructed of annealed soft copper that follows ASTM B3 and ASTM B8 standards.
Insulation:
The cable is insulated with a thermoset plastic jacket (PVC) that is flame-retardant, sunlight-resistant, lead-free, strong, and stable. Without being too bulky, it ensures that the cable can be used in harsh conditions. The jacket is color-coded in accordance with ICEA Method 4.
thermoplastic high heat-resistant nylon. Known for versatility and durability, it is the most common type of building cable. The double marking THHN /THWN-2 indicates that the electrical wire is equally suitable for wet and dry conditions (The letter "W" means water-safe). Additionally, the cable is resistant to corrosion, excessive dryness, and the impact of chemicals. The building wire is rated 90 degrees Celsius in both wet and dry locations. The electrical wire is rated at 600 V.
THHN Applications include:
• Building Wiring: This encompasses everything from lighting circuits to outlets in homes, commercial buildings, and industrial facilities.
• Conduit and Cable Trays: THHN is designed to be pulled through conduit, making it ideal for structured wiring systems in commercial and industrial settings. It's also commonly used in cable trays in industrial facilities.
• Control Systems: THHN can be used for wiring control circuits, including those for machinery, HVAC systems, and other building automation components.
• Machine Tool Wire: In manufacturing and industrial environments, THHN is commonly used to wire machine tools and equipment.
• Large Appliances: THHN wires can be used for connections inside large appliances like ovens, ranges, and HVAC units.
• Motor Connections: For connecting motors in both residential and commercial settings
• Feeders and Branch Circuits: In electrical distribution systems, THHN wires can serve as feeders (which extend from service panels to subpanels or major appliances) and branch circuits (which extend from panels to outlets, lights, or individual appliances).
• Service Entrance: While specific SE cables exist for this purpose, THHN wires can also be used for service entrances when appropriately configured and protected.
Particular 8 THHN applications are:
• Residential Subpanels: Power distribution in larger homes or homes with outbuildings.
• Air Conditioning Units: For moderately-sized units both in residential and smaller commercial buildings.
• Water Heaters: Especially electric water heaters that require higher amperage.
ICEA S-73-532
UL 1277 (Resistant to flame, moisture, and sunlight)
UL 1581, UL 83, UL 1063 , UL 758
A-A59544
ASTM B3 and B8 conductor
ANSI/NFPA 70 for Safe Electrical Design and Installation
RoHS compliant
Safe For Commercial and Industrial Use
Color-coded #1-E2 per ICEA S-73-532
May be used in NEC Class I and II systems
May be used in Division 2 hazardous locations
Allowed for Exposed Run (ER) and be used in accordance with NEC
THHN THWN-2 Copper Building Wire Allowable Ampacity in Duct: 55 Amps
• Weight per 1,000 ft: 66 lbs
• Outside Diameter: 0.240 inches
• Conductors: Annealed Soft Copper per ASTM B3 and ASTM B8
• Number of Strands: 19
• Insulation: PVC
• Insulation Thickness (mils): 30
• Nylon Thickness (mils): 4
• Jacket: PVC
• Houston Wire Part #: HW001 00801