Belden 7201A Cable 24 AWG 2 Pairs Stage Lighting Flex Data Multi Conductor Cable

Belden 7201A Cable 24 AWG 2 Pairs Stage Lighting Flex Data Multi Conductor Cable

Select gauge from drop-down menu for prices:

Belden 7201A Cable 24 AWG 2 Pairs Stage Lighting Flex Data Multi Conductor Cable

Regular price $5.18 $3.45 Sale /per Foot

Belden 7201A Cable 24 AWG 2 Pairs Stage Lighting Flex Data Multi Conductor Cable

Description:
• 24 AWG stranded (41x40) bare copper conductors, twisted pairs, foam polyethylene insulation with skin, overall Beldfoil® (100% coverage), tinned copper braid shield (85% coverage), oil-resistant PVC jacket.

Insulation:
• Material: PE - Polyethylene
• PE - Polyethylene

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 41x40
• Conductor Material: Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride

Usage (Overall):
• Applications: Flex Data, RS232, RS485

Mechnical Characteristics (Overall):
• Operating Temperature Range: -20°C To +60°C
• UL Temperature Rating: 60°C
• Bulk Cable Weight: 43.500 lbs/1000 ft.
• Max. Recommended Pulling Tension: 68 lbs.
• Min. Bend Radius/Minor Axis: 3.200 in.
• Min. Bend Radius (Continuous Flexing): 4.500 in.
• Flex Cycle Rating: 1 Million

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CM
• CEC/C(UL) Specification: CM
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: RS Type: 232/485

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 15
• Nominal Velocity of Propagation VP (%): 72
• Max.Operating Voltage - UL: 300 V RMS
• Differential Impedance @ 1 MHz: 120 +/-15

Flame Test:
• UL Flame Test: UL1685 UL Loading

Suitability:
• Oil Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

Benefits And Features:
• Belden offers more than 25 variations for DMX / RS-485 applications
• Many of Belden's lighting cables are designed for industrial standards, and their rugged and resistant cable options are suitable for many indoor and outdoor lighting challenges

technical specification:
awg 24
# pair 2
stranding 41x40
no. of conductors 4
conductor material tinned copper
dia. (in.) -
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal dia. (in.) 0.322
belden cable part number 7201A