Description:
• Low cap 24 AWG stranded (7x32) TC conductors, plenum, foam FEP insulation, twisted pairs, overall Beldfoil (100% coverage) + TC braid shield (90% coverage), 24 AWG stranded TC drain wire, FEP jacket.

Insulation:
• Trade Name: Teflon®
• Material: PE - Polyethylene
• Wall Thickness (in.): 0.023

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Conductor Material: Tinned Copper

Outer Jacket:
• Trade Name: Teflon®
• Material: FEP - Fluorinated Ethylene Propylene

Mechnical Characteristics (Overall):
• Operating Temperature Range: -70°C To +150°C
• UL Temperature Rating: 150°C
• Bulk Cable Weight: 27 lbs/1000 ft.
• Max. Recommended Pulling Tension: 45.700 lbs.
• Min. Bend Radius/Minor Axis: 2.250 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 120
• Nom. Capacitance Conductor to Conductor (pF/ft): 12
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 22
• Nominal Velocity of Propagation VP (%): 76
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 24
• Nom. Outer Shield DCR @ 20°C (Ohm/1000 ft): 3.1
• Max.Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 4 Amps per conductor @ 25°C

Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6

Suitability:
• Suitability - Indoor: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 82841, 89841

Benefits And Features:
• Belden offers more than 25 variations for DMX / RS-485 applications
• Many of Belden's lighting cables are designed for industrial standards, and their rugged and resistant cable options are suitable for many indoor and outdoor lighting challenges

technical specification:
awg 24
# pair 1
stranding 7x32
no. of conductors 2
conductor material tinned copper
dia. (in.) -
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal dia. (in.) 0.202
belden cable part number 89841