Belden 2221 Cable 26 AWG 1 Pair Stage Lighting Bare Copper PVC Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable Stage Lighting Cable
- Belden 9841 Cable 24 AWG 1 Pair Stage Lighting Low Capacitance Computer Non Plenum PVC Jacket Cable
- Belden 8241 Cable 23 AWG 1 Coax Stage Lighting 75 Ohm Plenum PVC Jacket Cable
- Belden 89841 Cable 24 AWG 1 Pair Stage Lighting Low Cap. Computer and Computer P.O.S. Plenum Cable
- Belden 9841NH Cable 24 AWG 1 Pair Stage Lighting GreenChoice Multi Conductor Cable
- Belden 7200A Cable 24 AWG 1 Pair Stage Lighting Bare Copper Flex Data Cable
- Belden 9842 Cable 24 AWG 2 Pairs Stage Lighting Tinned Copper Non Plenum Cable
- Belden 82842 Cable 24 AWG 2 Pairs Stage Lighting Tinned Copper Plenum Flamarrest Jacket Cable
- Belden 89842 Cable 24 AWG 2 Pairs Stage Lighting Low Cap. Computer and Computer P.O.S. Cable
- Belden 9842NH Cable 24 AWG 2 Pairs Stage Lighting GreenChoice Low Capacitance Computer Cable
- Belden 7201A Cable 24 AWG 2 Pairs Stage Lighting Flex Data Multi Conductor Cable
- Belden 9729 Cable 24 AWG 2 Pairs Stage Lighting Shielded Twisted Pair PVC Jacket Cable
- Belden 82729 Cable 24 AWG 2 Pairs Stage Lighting Multi Pair Snake Cable
- Belden 89729 Cable 24 AWG 2 Pairs Stage Lighting Multi Pair Snake Fluorocopolymer Jacket Cable
- Belden 1502R Cable 22 AWG And 18 AWG 1 Pair Stage Lighting Multimedia Control Cable
- Belden 1502P Cable 22 AWG And 18 AWG 1 Pair Stage Lighting Plenum Flamarrest Jacket Cable
- Belden 1502SB Cable 22 AWG And 18 AWG 1 Pair Stage Lighting LSZH Jacket Cable
- Belden 1800B Cable 24 AWG 1 Pair Stage Lighting Non Plenum PVC Jacket Cable
- Belden 1353A Cable 24 AWG 1 Pair Stage Lighting Non Plenum AES/EBU Digital Audio Cable
- Belden 1801B Cable 24 AWG 1 Pair Stage Lighting Plenum Tinned Copper Cable
- Belden 1800F Cable 24 AWG 1 Pair Stage Lighting Digital Audio Flexible Cable
- Belden 19109 Cable 18 AWG 3 Conductors Stage Lighting Portable Cordage UL/CSA Cable
- Belden 19108 Cable 16 AWG 3 Conductors Stage Lighting Non Plenum Smooth Jacket Cable
- Belden 19107 Cable 14 AWG 3 Conductors Stage Lighting Portable Cordage Cable
- Belden 19106 Cable 12 AWG 3 Conductors Stage Lighting Flexible 600V Power Cable
- Belden 19105 Cable 10 AWG 3 Conductors Stage Lighting Non Plenum 600V Power Cable
- Belden 27139A Cable 10 AWG 3 Conductors Stage Lighting 600V Type TC PVC Jacket Cable
- Belden 27150A Cable 8 AWG 3 Conductors Stage Lighting 600V Type TC Bare Copper Cable
- Belden 1588A Cable 24 AWG 2 Pairs Stage Lighting 5e Nonbonded Pair Cable
- Belden 1588R Cable 24 AWG 2 Pairs Stage Lighting 5e Nonbonded Pair PVC Jacket Cable
- Belden 1590A Cable 24 AWG 2 Pairs Stage Lighting Flamarrest Jacket Solid Bare Copper Cable
- Belden 1212 Cable 24 AWG 4 Pairs Stage Lighting Enhanced Category 5E Nonbonded Pair Cable
- Belden 1304A Cable 24 AWG 4 Pairs Stage Lighting CatSnake Bare Copper Cable
- Belden 1305A Cable 24 AWG 4 Pairs Stage Lighting UpJacketed CatSnake Cable
- Belden 1304A4 Cable 24 AWG 16 Pairs Stage Lighting Flexible Bare Copper Cable
Description:
• 26 AWG stranded (30x40) BC conductors cabled with fillers, Datalene® insulation, conductors cabled with fillers, TC "French Braid" Shield (95% coverage), Belflex® PVC jacket.
Insulation:
• Trade Name: Datalene®
• Material: FHDPE - Foam High Density Polyethylene
Outer Jacket:
• Trade Name: Belflex®
• Material: PVC - Polyvinyl Chloride
Mechnical Characteristics (Overall):
• Operating Temperature Range: -20°C To +60°C
• Bulk Cable Weight: 16.500 lbs/1000 ft.
• Max. Recommended Pulling Tension: 34 lbs.
• Min. Bend Radius/Minor Axis: 1.750 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 03/10/2011
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: AES/EBU Digital Audio
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 110
• Nom. Capacitance Conductor to Conductor (pF/ft): 13.000
• Nominal Velocity of Propagation VP (%): 78.000
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 36.000
• Nom. Outer Shield DCR @ 20°C (Ohm/1000 ft): 6.600
• Max.Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.9 Amps per conductor @ 25°C
Suitability:
• Indoor: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
Benefits And Features:
• Belden offers more than 25 variations for DMX / RS-485 applications
• Many of Belden's lighting cables are designed for industrial standards, and their rugged and resistant cable options are suitable for many indoor and outdoor lighting challenges
technical specification: | |
awg | 26 |
# pair | 1 |
stranding | 30x40 |
no. of conductors | 2 |
conductor material | Bare Copper |
dia. (in.) | - |
outer shield - type | French Braid |
outer shield - material | Tinned Copper |
overall cable - nominal dia. (in.) | 0.170 |
belden cable part number | 2221 |