2 AWG Clemson Single Conductor Aluminum URD Cable 600V
Select gauge from drop-down menu for prices:
- Single Conductor Aluminum URD Direct Burial Cable 600V
- 6 AWG Princeton Single Conductor Aluminum URD Cable 600V
- 4 AWG Mercer Single Conductor Aluminum URD Cable 600V
- 1 AWG Kenyon Single Conductor Aluminum URD Cable 600V
- 1/0 AWG Harvard Single Conductor Aluminum URD Cable 600V
- 2/0 AWG Yale Single Conductor Aluminum URD Cable 600V
- 3/0 AWG Tufts Single Conductor Aluminum URD Cable 600V
- 4/0 AWG Beloit Single Conductor Aluminum URD Cable 600V
- 250 MCM Hofstra Single Conductor Aluminum URD Cable 600V
- 300 MCM Gonzaga Single Conductor Aluminum URD Cable 600V
- 350 MCM Rutgers Single Conductor Aluminum URD Cable 600V
- 500 MCM Emory Single Conductor Aluminum URD Cable 600V
- 600 MCM Duke Single Conductor Aluminum URD Cable 600V
- 700 MCM Furman Single Conductor Aluminum URD Cable 600V
- 750 MCM Sewanee Single Conductor Aluminum URD Cable 600V
- 1000 MCM Fordham Single Conductor Aluminum URD Cable 600V
Description:
2 AWG Clemson is a single conductor cable used for secondary power distribution in homes. It has an Aluminum conductor that can be availed in compressed wiring or in concentric lay stranding. The cable operates at 90°C at an allowable ampacity of 155 amps. However, when in ducts its Ampacity is 115. The underground cable has polyethylene insulation.
Applications:
#2 single conductor secondary distribution wire is commonly used in residential settings. It is specifically meant for underground power transmissions this is resistant to rocky obstacles commonly found in these areas. Furthermore it can be used as a direct burial wire which involves direct insertion in to the soil with the use of a conduit or duct for protection. However its performance can be affected in these applications if the maximum temperature rating exceeds 90°C in both wet and dry locations.
Conductors:
The conductors are made of aluminum which are compressed at 1350-H19.
Insulation:
Aluminum URD cable has a cross-linked polyethylene insulation (XLPE) which can withstand high temperatures of up to 90°C.
Features:
• Robust and sturdy insulation
• It is resistant to high temperatures
• 600 volt URD cable
• Moisture and chemical resistant
Standards:
• ASTM B-230
• ASTM B-609
• ICEA S-105-692
• RUS ACCEPTED
Technical Specifications: | |
Phase Conductor Insulation Thickness: | 60mls |
Size AWG: | 2 |
Stranding: | 7 |
Diameter Individual Wire Aluminum (Inches): | 0.283 |
Diameter Complete Cable (O.D.) (Inches): | 0.403 |
Weight Per 1000ft Total (Lbs.): | 92 |
Allowable Ampacity 90C (Amps): | 155 |
Allowable Ampacity in Ducts (Amps): | 115 |