Belden 7804C Cable 16 AWG and 24 AWG SMPTE Camera 311M HDTV Composite Heavy Gauge Riser Cable

Belden 7804C Cable 16 AWG and 24 AWG SMPTE Camera 311M HDTV Composite Heavy Gauge Riser Cable

Belden 7804C Cable 16 AWG and 24 AWG SMPTE Camera 311M HDTV Composite Heavy Gauge Riser Cable

Description:
• 2 power conductors, SM fiber w/24 AWG and 16 AWG stranded (7x32 and 65x34) TC conductors, PVC insulation, TC braid shield (95% coverage), Belflex® jacket.

Insulation:
• Materials: PVC - Polyvinyl Chloride (24 AWG and 16 AWG)
• Diameters (in.): 0.050 (24 AWG) and 0.093 (16 AWG)

Outer Jacket:
• Trade Name: Belflex®
• Material: PVC Blend - Polyvinyl Chloride Blend

Strength Member:
• Overall Strength Member Diameter: .070
• Strength Member Material: 302 Stainless Steel
• Strength Member Insulation Material: PVC - Polyvinyl Chloride

Fiber:
Physical Characteristics:
• Number of Fibers: 2
• Mode Field Diameter @ 1310nm: 9.5 microns
• Clad Diameter: 125 microns
• Breakout Element Diameter: .079 in.
• Core-clad Concentricity Error: < to 1 micron
• Primary Coating Material: Acrylate
• Buffer Tube Diameter: 900 microns
• Breakout Element Material: PVC - Polyvinyl Chloride
• Buffer Tube Material: PVC - Polyvinyl Chloride

Optical Characteristics:
• Maximum Attenuation @ 1310nm: 0.8 dB/km

Usage (Overall):
Applications:
• SMPTE 311M HDTV Cable

Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -30°C To +60°C
• Bulk Cable Weight: 81.300 lbs/1000 ft.
• Max. Recommended Pulling Tension: 450 lbs.
• Min. Bend Radius/Minor Axis: 2.500 in.
• Flex Cycle Rating: UL1581, Sec. 1582: 15,000 Cycles @ 3.6
• Crush Resistance: Compression, FOTP-41: 397 lbs.
• Impact Resistance: FOTP-25: 20 Cycles @ 1.32 lbs.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR
• CEC/C(UL) Specification: CMG
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 07/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: SMPTE 311

Electrical Characteristics (Individual Shield):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 23.300 (24 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 4.300 (16 AWG)
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 2.800

Flame Test:
• UL Flame Test: UL1666 Vertical Shaft
• CSA Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suggested Connectors: SMPTE 304M Connectors

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 16 and 24
# conductors 2 and 2
stranding 65x34 and 7x32
conductor material tinned copper
dia. (in.) 0.059 and 0.024
outer shield - type braid
outer shield - material tinned copper
overall cable- nominal dia. (in.) 0.362
belden cable part number 7804C