600 Volt UL Type MC-HL, CT Use - HW305 1606T
Select gauge from drop-down menu for prices:
- 600 Volt UL Type MC-HL, CT Use, Single Pair and Triad
- 600 Volt UL Type MC-HL, CT Use - HW305 1601P
- 600 Volt UL Type MC-HL, CT Use - HW305 1601T
- 600 Volt UL Type MC-HL, CT Use - HW305 1602P
- 600 Volt UL Type MC-HL, CT Use - HW305 1604P
- 600 Volt UL Type MC-HL, CT Use - HW305 1604T
- 600 Volt UL Type MC-HL, CT Use - HW305 1608P
- 600 Volt UL Type MC-HL, CT Use - HW305 1612P
- 600 Volt UL Type MC-HL, CT Use - HW305 1624P
- 600 Volt UL Type MC-HL, CT Use - HW305 1636P
Technical Specifications: | |
Catalog Number | HW305 1606T |
Size AWG | 16 |
Pair or Triad | 6 Triad |
PVC-Nylon Insulation Thickness Mils | 15-4 |
Jacket Thickness Mils | 50 |
Class 1 Div. 2 Connector No. | 424MA04 |
Rain Tight Connector No. | 416MC05 |
Armor Diameter Inch | 1.07 |
Inner Jacket Overall Diameter Inch | 0.79 |
Inner Jacket Thickness Mils | 50 |
Overall Diameter Inch | 1.17 |
Net Weight Lbs/Mft | 560 |
Specifications:
- Impervious Continuously Welded Armor - Instrumentation Cable
- 300 Volt UL Type PLTC, ITC, 105°C
- Single Pair and Triad - Shielded
- Multiple Shielded Pairs or Triads with Overall Shield
- Aluminum Armor
- Copper Conductors
Application:
For use in harsh environments where maximum conductor and electrostatic interference protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for instrumentation and process and control applications in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for continuous use at 105°C in wet or dry locations, 130°C for emergency overload conditions, and 250°C for short circuit conditions. May be installed indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 300 volts. UL listed as, NEC Type MC per UL Standard 1569 and is approved for use in Class I, Division 2 hazardous locations. Impervious continuously welded and corrugated aluminum armor cable is recommended as an economical alternative to wire in conduit systems.
Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).
Insulation:
Flame-retardant PVC Individual Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.
Overall Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.
Communication Wire:
22AWG stranded bare copper wire with PVC insulation.
Inner Jacket:
Flame-retardant PVC
Armor:
Impervious continuously welded and corrugated aluminum.
Jacket:
Black sunlight-resistant PVC
Flame Tests:
- UL 1581 70,000 BTU/hr flame test
- ICEA 70,000 BTU/hr and 210,000 BTU/hr flame test
- IEEE 383 70,000 BTU/hr flame test
Color Code:
- ICEA Method 9: black and white for pairs and black, white and red for triads with printed number
Additional Standards:
- Individual conductors a UL listed as Type FPL
- Meets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test
Connectors:
- Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components
- Rain Tight: 416MC series – all nickel-plated brass