General Cable Armored Power 15kV 1/0 Gauge Shielded 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®
Select gauge from drop-down menu for prices:
- General Cable Armored Power 15kV Shielded 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®
- General Cable Armored Power 15kV 2 Gauge Shielded 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®
- General Cable Armored Power 15kV 1 Gauge Shielded 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®
- General Cable Armored Power 15kV 2/0 Gauge Shielded 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®
- General Cable Armored Power 15kV 4/0 Gauge Shielded 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®
- General Cable Armored Power 15kV 250MCM Shielded 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®
- General Cable Armored Power 15kV 350MCM Shielded 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®
- General Cable Armored Power 15kV 500MCM Shielded 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®
- General Cable Armored Power 15kV 750MCM Shielded 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®
Product Details
Conductor:
• Bare annealed copper per ASTM B3
• Compact stranding per ASTM B496
Extruded Strand Shield (ESS): Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072
Insulation: 220 mils Ethylene Propylene Rubber (EPR) insulation per ICEA S-93-639 and UL 1072
Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer, free stripping from the insulation per ICEA S-93-639 and UL 1072
Shield: 5 mil annealed bare copper tape with 25% overlap
Phase Identification: Color-coded polymeric identification tape laid under the shield – black, red and blue
Grounding Conductors:
• Class B stranded bare annealed copper grounding conductor
• Sized in accordance with UL 1072 and NEC Article 250
Cable Assembly:
• Insulated and grounding conductors are cabled together with non-hydroscopic fillers when required
• Binder tape is applied over the cabled core
CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL Standards 1569 and 2225
• CCW armor conductivity meets the grounding requirements of NEC Article 250
Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -60°C
Applications:
• CCW armored medium-voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods
• For use on feeders and branch circuits for power distribution systems per NEC Articles 328 and 330
• For use in Class I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505
• Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart
• Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded in concrete
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute
Features:
• CCW armor provides an impervious barrier to moisture, gas and liquids and meets grounding requirements of UL 1072 and the NEC
• Triple Extrusion: The strand shield, EPR insulation and insulation shield are all extruded in one operation
• General Cable’s EPR insulation system has outstanding corona resistance and high dielectric strength, and it provides electrical stability under stress
• Meets cold bend at -55°C
• 105°C continuous operating temperature, wet or dry
• 140°C emergency rating
• 250°C short circuit rating
Specifications:
Design Adherence:
• CEA S-93-639/WC74, 5-46 kV Shielded Power Cables
• AEIC CS8 Specification for Shielded Power Cable, 5 – 46 kV
• UL 1072 Medium-Voltage Power Cables
• UL 1569 Metal Clad Cables
• UL 2225 Cables and Cable Fittings for Use in Hazardous Locations
• UL 1309 Marine Shipboard Cable
Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• CSA FT4
• IEEE 1202 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEC 60332-3 Cat. A
Compliances:
• UL Type MV-105 or UL Type MC-HL, SUN RES, CT USE, DIR BUR, -40°C, FT4, UL File # E90501
• UL Listed Marine Shipboard, UL File # E85994
• CSA Type HL, SR, FT4, -40°C, CSA File # 27161
• American Bureau of Shipping (ABS) Listed for CWCMC
technical specification: | |
cond. size (awg/kcmil) |
1/0 (19/W)(53.5 mm²)
|
no. of cond. | 3 |
insulation thickness(mils) | 220 |
insulation thickness(mm) | 5.6 |
nominal o.d. over insulation(inches) | 0.83 |
nominal o.d. over insulation(mm) | 21.1 |
bare ground (awg) | 4 |
nominal core o.d.(inches) | 1.96 |
nominal core o.d.(mm) | 49.8 |
nominal armor o.d.(inches) | 2.32 |
nominal armor o.d.(mm) | 58.9 |
jacket thickness(mils) | 75 |
jacket thickness(mm) | 1.91 |
nominal overall o.d.(inches) | 2.48 |
nominal overall o.d.(mm) | 63.0 |
approximate net weight(lbs/1000 ft)
|
3,190 |
approximate net weight(kg/1000 m) | 4,747 |
ampacity (in air¹) | 240 |
ampacity(direct burial²) | 255 |
catalog number | 9840.11003104 |