Belden 29030 18 AWG 2 Conductors 600V ACIC Multi Conductor Armored Cable
Select gauge from drop-down menu for prices:
- Belden 18 AWG CSA Control 600V ACIC 7x26 Armored Unshielded Cable
- Belden 29031 18 AWG 3 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29032 18 AWG 4 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29033 18 AWG 5 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29034 18 AWG 6 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29035 18 AWG 7 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29036 18 AWG 8 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29038 18 AWG 10 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29040 18 AWG 12 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29043 18 AWG 15 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29048 18 AWG 20 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29053 18 AWG 25 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29058 18 AWG 30 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29068 18 AWG 40 Conductors 600V ACIC Multi Conductor Armored Cable
- Belden 29078 18 AWG 50 Conductors 600V ACIC Multi Conductor Armored Cable
Description:
• 18 AWG stranded (7x26) bare copper conductors, 18 AWG bare copper ground wire, .030x1A; (.76mm) XLPE insulation, PVC inner jacket, aluminum interlocked armor, PVC outer jacket.
Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 18
• Ground Wire Stranding: 7x26
• Conductor Material: BC - Bare Copper
Insulation:
• Material: XLPE - Cross Linked Polyethylene
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 8.128
• Outer Jacket over Armor (y/n): Y
Outer Jacket over Armor:
• Outer Jacket Material over Armor (y/n): PVC - Polyvinyl Chloride
Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
• Diameter over Armor: 0.52
Mechanical Charactertistics (Overall):
• Wet Temperature Range: -40°C To +90°C
• Dry Temperature Range: -40°C To +90°C
• Non-UL Temperature Rating: 90°C Wet/Dry
• Bulk Cable Weight: 242.577 Kg/Km
• Max. Recommended Pulling Tension: 115.653 N
• Min. Bend Radius/Minor Axis: 187.960 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#239, HAZ LOC, C22.2#0.3 Clause 4.31 Low Acid Gas
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Flame Test:
• CSA Flame Test: FT4
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 18 |
# conductors | 2 |
stranding | 7x26 |
no. of conductors | 2 |
conductor material | bare copper |
outer shield - material | unshielded |
overall cable- nominal dia. (mm) | 15.748 |
belden cable part number | 29030 |