Belden 581855 16 AWG 3 Pairs Spec 39-2 Communications Stranded Cable
Select gauge from drop-down menu for prices:
- Belden IMSA Spec 39-2 Aerial and Duct 300V Communications Cable
- Belden 580481 19 AWG 3 Pairs Spec 39-2 Communications Solid Cable
- Belden 581718 19 AWG 3 Pairs Spec 39-2 Communications Stranded Cable
- Belden 603434 19 AWG 6 Pairs Spec 39-2 Communications Solid Cable
- Belden 581164 19 AWG 12 Pairs Spec 39-2 Communications Stranded Cable
- Belden 581751 16 AWG 12 Pairs Spec 39-2 Communications Solid Cable
- Belden 581258 16 AWG 25 Pairs Spec 39-2 Communications Solid Cable
Description:
• 16 AWG stranded (7x24) bare copper conductors, HDPE insulation, corrugated copper tape shield, PVC jacket.
Insulation:
• Material: HDPE - High Density Polyethylene
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• Min. Bend Radius/Minor Axis: 149.860 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• IMSA Specification: 39-2
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 13.4521
Suitability:
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 16 |
# pairs | 3 |
solid or stranded | 7 strand |
no. of conductors | 6 |
conductor material | bare copper |
outer shield - type | tape |
outer shield - material | corrugated copper tape |
overall cable- nominal dia. (mm) | 14.884 |
belden cable part number | 581855 |