Draka Cable 535 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored Cable 036035
Select gauge from drop-down menu for prices:
- Draka Cable Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored or Armored and Sheathed Cable
- Draka Cable 1/0 AWG Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored Cable 036028
- Draka Cable 2/0 AWG Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored Cable 036029
- Draka Cable 4/0 AWG Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored Cable 036030
- Draka Cable 262 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored Cable 036031
- Draka Cable 313 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored Cable 036032
- Draka Cable 373 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored Cable 036033
- Draka Cable 444 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored Cable 036034
- Draka Cable 646 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored Cable 036036
- Draka Cable 777 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Unarmored Cable 036037
- Draka Cable 1/0 AWG Bostrig Type P VFD Power 2000V Shielded Three Conductor Armored and Sheathed Cable 036038
- Draka Cable 2/0 AWG Bostrig Type P VFD Power 2000V Shielded Three Conductor Armored and Sheathed Cable 036039
- Draka Cable 4/0 AWG Bostrig Type P VFD Power 2000V Shielded Three Conductor Armored and Sheathed Cable 036040
- Draka Cable 262 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Armored and Sheathed Cable 036041
- Draka Cable 313 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Armored and Sheathed Cable 036042
- Draka Cable 373 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Armored and Sheathed Cable 036043
- Draka Cable 444 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Armored and Sheathed Cable 036044
- Draka Cable 535 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Armored and Sheathed Cable 036045
- Draka Cable 646 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Armored and Sheathed Cable 036046
- Draka Cable 777 MCM Bostrig Type P VFD Power 2000V Shielded Three Conductor Armored and Sheathed Cable 036047
Conductors: Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.
Insulation: Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580 (2001).
Ground Conductors: All Bostrig Type P-VFD Cables listed in this specification sheet are built using system grounds equal to the aggregate cross-section of a phase conductor and can be in contact withor isolated from the overall shield. A system ground is REQUIRED for supplying power from the switchboard to the inverter and then to the motor. If the VFD cable is only being used between the motor and the inverter, a cable with a lesser ground can be utilized.
Shield: Braided tinned copperand aluminum polyester tape for 100% coverage
Jacket: Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580. Thickness as shown in tables on opposite page.
Armor (optional): Braided bronze in accordance with IEEE 1580.
Sheath: Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene as required in IEEE 1580. Thickness as shown in tables on opposite page.
Applications:
• Bostrig™ Type P shielded three conductor VFD Marine and Offshore Cable is designed specifically for use with variable frequency AC motor drives. This cable is designed to significantly mitigate the deleterious effects of high frequency harmonics and electromagnetic interference (EMI) on the motor /drive system as well as the adjacent environment.
• Bostrig™ VFD cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based muds (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored and sheathed) and complies with UL 1277 Type TC-ER extended runs requirements.
• The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3).
• This product may be manufactured in an unarmored or armored and sheathed version.
Approvals:
• IEEE 1580 and IEEE 45- Marine Shipboard Cable
• UL 1309- Marine Shipboard Cable Type X110
• CSA 22.2 No. 245- Marine Shipboard Cable Type X110
• Det Norske Veritas (DNV)
• American Bureau of Shipping (ABS)
• Transport Canada Approved AMS400-20-2
• Transport Canada 8700-20-2
• Lloyd’s Register of Shipping (LRS)
• United States Coast Guard-46CFR
Features/Ratings:
• Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact
• High strand count conductors provide superior flexibility
• Higher allowable conductor operating temperature results in increased ampacity
• Hold bend/ cold impact of -40°/ -35°C in accordance with CSA 22.2 No. 0.3
• Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A
• Arctic neoprene jacket allows ease of stripping in all temperatures
• Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6/1kV
• This product may be manufactured in an unarmored or armored and sheathed version
• Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore
• Unarmored cables suitable for use in Class I, Division 2 hazardous locations offshore
• Meets requirements for UL 1277 Type TC-ER for exposed runs
technical specification: | |
conductor size - awg/mcm | 535 |
conductor size- mm2
|
271.2 |
type designation | tp(obs)n-535 |
ground size - awg/mcm | 310 |
ground size - mm2 | 92.1 |
sheath thickness - in | n/a |
sheath thickness - mm | n/a |
cable diameter (nominal) - in | 3.010 |
cable diameter (nominal) - mm | 76.5 |
inductance - Ω/kft | 0.09 |
inductance - Ω/km | 0.3 |
capacitance - pf/ft | 291 |
capacitance - pf/m | 954 |
calculated ampacity† (measured @ ºc) - 95 | 417 |
calculated ampacity† (measured @ ºc) - 100 | 443 |
calculated ampacity† (measured @ ºc) - 110 | 475 |
calculated ampacity† (measured @ ºc) - 125* | 608 |
cable weight (approximate) - lbs/mft | 9695 |
cable weight (approximate) - kg/km | 14430 |
draka cable part number | 036035 |