General Cable EmPowr® 500kcmil 35 kV Copper Tape PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation 345 mils
Select gauge from drop-down menu for prices:
- General Cable EmPowr® 35 kV Copper Tape PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation
- General Cable EmPowr® 1/0 AWG 35 kV Copper Tape PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation 345 mils
- General Cable EmPowr® 2/0 AWG 35 kV Copper Tape PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation 345 mils
- General Cable EmPowr® 3/0 AWG 35 kV Copper Tape PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation 345 mils
- General Cable EmPowr® 4/0 AWG 35 kV Copper Tape PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation 345 mils
- General Cable EmPowr® 250kcmil 35 kV Copper Tape PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation 345 mils
- General Cable EmPowr® 350kcmil 35 kV Copper Tape PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation 345 mils
- General Cable EmPowr® 750kcmil 35 kV Copper Tape PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation 345 mils
- General Cable EmPowr® 1000kcmil 35 kV Copper Tape PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation 345 mils
Product Details
Complete Cable: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper tape (helically applied) and overlaying black PVC jacket are applied over the cable core. These products meet the latest requirements of ANSI/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated shielded power cable.
Conductor: Solid or Class B compressed concentric lay stranded 1350 aluminum.
Conductor Shield: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.
Insulation: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).
Insulation Shield: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.
Copper Tape: Flat uncoated 5-mil-thick copper tape helically applied with minimum 15% overlap.
Jacket: Black, non-conducting, sunlight-resistant Polyvinyl Chloride (PVC).
Features and Benefits:
• Lead-free environmentally friendly cable
• Triple-extruded for clean interfaces
• Dry nitrogen cure for enhanced performance
• Class 10,000 environment utilized for cable core material handling
• Excellent moisture resistance
• High dielectric strength
• Low dielectric loss
• Excellent resistance to water treeing
• Clean-stripping insulation shield
• Sunlight-resistant
Temperature Rating:
• Normal - 90°C
• Emergency* - 130°C
• Short Circuit - 250°C
Applications: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of threephase medium-voltage power. These cables may be installed in ducts or direct buried.
Options:
• Copper conductors
• STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610
• True Triple Extrusion
• UltraPowr® smoother and cleaner semiconducting conductor shield
• Low-strip insulation shield
• 3 X 1/C triplex or parallel
• 3 shielded cores cabled with fillers, with or without ground conductor, and with an overall jacket
• Type MV-90 UL 1072
• TRXLPE Class III insulation for 105°/140°C temperature rating
• Type MV-105 UL 1072
• UL Listed
• EPR insulation – see Uniblend® in our Industrial catalog
technical specifications: | |
compressed conductor(al awg or kcmil) | 500 |
compressed conductor(no. of wires) | 37 |
diameter (1) inches(min. insulation) | 1.480 |
diameter (1) inches(max. insulation)
|
1.580 |
diameter (1) inches(5 mil copper tape) | 1.597 |
diameter (1) inches(pvc jacket) | 1.816 |
nominal jacket thkn. inches (1) | 0.110 |
approx. weight (1) lb/1000 ft(al cond.) | 468 |
approx. weight (1) lb/1000 ft(cu shield)
|
113 |
approx. weight (1) lb/1000 ft(total) | 1544 |
ampacity (2) (direct buried) | 510 |
ampacity (2) (in duct) | 410 |