Helukabel 14 AWG 5 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22218
Select gauge from drop-down menu for prices:
- Helukabel PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable
- Helukabel 19 AWG 2 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22200
- Helukabel 19 AWG 3 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22201
- Helukabel 19 AWG 4 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22202
- Helukabel 19 AWG 5 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22203
- Helukabel 19 AWG 7 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22204
- Helukabel 18 AWG 2 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22205
- Helukabel 18 AWG 3 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22206
- Helukabel 18 AWG 4 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22207
- Helukabel 18 AWG 5 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22208
- Helukabel 18 AWG 7 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22209
- Helukabel 16 AWG 2 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22210
- Helukabel 16 AWG 3 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22211
- Helukabel 16 AWG 4 Cores PUR-GELB JB Version Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22212
- Helukabel 16 AWG 5 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22213
- Helukabel 16 AWG 7 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22214
- Helukabel 14 AWG 2 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22215
- Helukabel 14 AWG 3 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22216
- Helukabel 14 AWG 4 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22217
- Helukabel 14 AWG 7 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22219
- Helukabel 12 AWG 4 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22221
- Helukabel 12 AWG 5 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22222
- Helukabel 2 AWG 4 Cores PUR-GELB Yellow PVC Inner Sheath High Abrasion Coolant Resistant Meter Marking Cable 22233
Product Details
Technical Data:
• Special-PVC/PUR control cable adapted to DIN VDE 0285-525-1/DIN EN 50525-1
Temperature Range
• Flexing -15°C to +80°C
• Fixed installation -40°C to +80°C
Nominal Voltage
• U0/U 300/500 V
Test Voltage
• 3000 V
Breakdown Voltage
• Min. 6000 V
Insulation Resistance
• Min. 20 MOhm x km
Minimum Bending Radius
• Flexing 7,5x cable Ø
• Fixed installation 4x cable Ø
Radiation Resistance
• Up to 100x106 cJ/kg (up to 100 Mrad)
Cable Structure:
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of special PVC compound type TI2 adapted to DIN VDE 0207-363-3 / DIN EN 50363-3
• Core identification to DIN VDE 0293-308
- up to 5 cores coloured
- from 6 cores, black with continuous white numbering
• GN-YE conductor, 3 cores and above
• Cores stranded in layers with optimal lay-length
• Inner sheath of PVC guarantees easy cable stripping
• Outer sheath of PUR compound type TMPU to DIN EN 50363-10-2
• Sheath colour yellow (RAL 1021) also available in other colours on request
• with meter marking
Properties:
• High flexibility at low temperature
• High abrasion resistance
• Resistant to
Oils and fats
Non-alcoholic fuels and kerosene
Atmospheric influences
UV-radiation
Oxygene and ozone
Microbes and rotting
Sea and waste water
Vibrations
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Note:
• G = with green-yellow conductor
• x = without green-yellow conductor (OB).
• Art.no. 22212 = JB-version.
• Art.no. 22220 = JZ-version.
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
Application:
• Robust control cable with an outstanding resistance to oil and abrasion. Suitable for use in tool making and machine industries, steel works, on building sites and in the oil and coal industries. The cable can also be used for portable tools. etc. To be recommended if the cable comes into contact with chemical agents.
technical specification: | |
awg-no. | 14 |
no.cores x cross-sec. mm² | 5 G 2,5 |
outer ø app. mm | 13,7 |
cop. weight kg/km | 120,0 |
weight app. kg/km | 253,0 |
helukabel part number | 22218 |