Helukabel 22 AWG 8 Pairs SUPER-PAAR-TRONIC 340-C-PUR Cable For Drag Chains Halogen Free EMC Preferred Type Meter Marking Cable 49845

Helukabel 22 AWG 8 Pairs SUPER-PAAR-TRONIC 340-C-PUR Cable For Drag Chains Halogen Free EMC Preferred Type Meter Marking Cable 49845

Select gauge from drop-down menu for prices:

Helukabel 22 AWG 8 Pairs SUPER-PAAR-TRONIC 340-C-PUR Cable For Drag Chains Halogen Free EMC Preferred Type Meter Marking Cable 49845
Helukabel 22 AWG 8 Pairs SUPER-PAAR-TRONIC 340-C-PUR Cable For Drag Chains Halogen Free EMC Preferred Type Meter Marking Cable 49845

Technical data:
• Special drag chain cable, stranded in pairs

Temperature range
• flexing -30°C to +80°C
• fixed installation -40°C to +80°C

Nominal voltage
• 300 V

Test voltage
• core/core 1500 V
• core/screen 1000 V

Insulation resistance
• min. 100 MOhm x km

Mutual capacitance
• core/core approx. 60 nF/km

Minimum bending radius
• for permanent bending
flexing
• at 0,25 mm²: 7,5x cable Ø
• at 0,5 - 1 mm²: 10x cable Ø
fixed installation
• at 0,25 mm²: 4x cable Ø
• at 0,5 - 1 mm²: 5x cable Ø

Coupling resistance
• max. 250 Ohm/km

Radiation resistance
• up to 100x106 cJ/kg (up to 100 Mrad)

Cable structure:
• Bare copper conductor, extra fine wire, acc. to DIN VDE 0295 cl.6, col. 4, BS 6360 cl.6 and IEC 60228 cl.6
• Core insulation of PP
• Core identification to DIN 47100
• Cores stranded in pairs, pairs stranded torsion-free in layers with optimal lay length
• Wrapping over the outer layer
• Braided screen of tinned Cu wires, coverage approx. 85%
• Core wrapping with fleece
• Outer sheath of full polyurethane compound type TMPU to DIN VDE 0207-363-10-2 / DIN EN 50363-10-2 and acc. to UL Std.1581 tab.50.227
• Sheath colour: grey (RAL 7001)
• With meter marking

Properties:
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
• Halogen-free
• Weather, ozone and UV resistant
• Chemical resistance to solvents, acids, alkalis and hydraulic fluids

Tests:
• PUR outer sheath, flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)
• Oil resistance acc. to DIN VDE 0473-811-404/ DIN EN 60811-404

Note:
• AWG sizes are approximate equivalent values. The actual cross section is in mm².

Advantages:
• Very high resistance to mechanical stresses
• Very good alternating bending strength
• High tear, abrasion and impact resistance, even at low temperatures

technical specification:
awg-no. 22
no.pairs x no.cores x cross-sec. mm² 8 x 2 x 0,34
outer ø app. mm 11,9
cop. weight kg/km 107,5
weight app. kg/km 214,0
helukabel part number 49845

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question