HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 4 Conductors
Select gauge from drop-down menu for prices:
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 14 AWG - 2 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 14 AWG - 3 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 14 AWG - 4 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 14 AWG - 5 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 14 AWG - 7 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 14 AWG - 9 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 14 AWG - 12 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 14 AWG - 19 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 14 AWG - 37 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 12 AWG - 2 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 12 AWG - 3 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 12 AWG - 4 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 12 AWG - 5 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 12 AWG - 7 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 12 AWG - 9 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 12 AWG - 12 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 12 AWG - 19 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 12 AWG - 37 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 2 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 3 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 5 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 7 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 9 Conductors
- HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 12 Conductors
Technical Specifications: | |
Catalog Number/HWC Part # | HW290 01004 |
Size AWG/kcmil | 10 |
Size (mm2) | 5.2 |
Number of Conductors | 4 |
Grounding Conductor AWG/kcmil | 10 |
Nominal Diameter (inches) | 0.740 |
Weight (lbs./1000 ft.) | 335 |
90°C NEC Ampacity | 30 |
75°C NEC Ampacity | 28 |
DC Resistance at 25°C(Ohms/1000 ft.) | 1.15 |
AC Resistance at 90°C, 60 Hz (Ohms/1000 ft.) | 1.44 |
Voltage Drop (Volts/Amp/1000 ft.) | 2.031 |
HL Listed | * |
Specifications:
- HW290
- Listed CIR® Control Cable*
- Multi-Conductor + Ground
- 0.6/1kV 90°C Gexol® Insulation
Application:
Designed and constructed to be a flexible alternative to Type MC cable where crush and impact protection in arctic conditions is required.
Conductors:
Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.
Insulation:
Gexol cross-linked flame retardant polyolefin, meets requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. 600V/IEC 1000V.
Grounding Conductor:
Soft annealed, flexible stranded, insulated, tinned copper sized in accordance with UL 1277.
Jacket:
A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 1309/CSA 245 and IEEE 1580.
Ratings & Approvals :
- 90°C temperature rating
- UL Listed as Marine Shipboard Cable (E111461)
- UL Listed as Type TC-ER
- UL Listed as Type TC-ER-HL*
- American Bureau of Shipping (ABS) (99-BT5905-X)
- Flame Retardant – IEEE 1202
- Suitable for use in Class I, Div 2 & Zone 2 environments
- Suitable for use in Class I, Div 1 & Zone 1 environments*
- *Cables up to 1” in OD
Features:
- Complies with the requirements for TC-ER-HL* per UL 2225
- Gas & vapor tight – impervious to water and air
- Smaller bend radius (up to 40% smaller) than Type MC
- Reduced tray fill (up to 35% less) compared to Type MC
- Considerably more flexible than Type MC
- Brittle point as per ASTM D 746-07 exceeds -65°C for Jacket and -75°C for Insulation
- Exceeds CSA cold bend / cold impact (-40°C / -35°C)
Power and Control Cable Color Legend: |
|
Conductor # | Color |
1 | Black |
2 | Red |
3 | Blue |
4 | Orange |