General Cable Polyrad® XT 777kcmil Flexible Wire and Cable 600V Single-Conductor Dual Rated 125C/110C

General Cable Polyrad® XT 777kcmil Flexible Wire and Cable 600V Single-Conductor Dual Rated 125C/110C

Select gauge from drop-down menu for prices:

General Cable Polyrad® XT 777kcmil Flexible Wire and Cable 600V Single-Conductor Dual Rated 125C/110C
Polyrad XT 777kcmil Flexible Wire and Cable 600V Single-Conductor Dual Rated 125C/110C

Conductor:  20 AWG thru 1111 kcmil soft annealed tinned copper per ASTM B33, B8 and B172 

Insulation: Polyrad® XT flame-retardant, low-smoke irradiated Cross-linked Polyolefin (XLPO) 

Options: 
• Available in multi-conductor constructions 
• Class K stranding 
• Available in colors other than dark gray 

Applications: 
• Ideally suited for use where environmental factors require cable characteristics to perform with a high degree of flame retardancy and excellent moisture-stable electrical values. Where reliability is the major concern and where maximum performance will be demanded 
• Engineered and manufactured for both original equipment and retrofit use in power and control circuits and in motor leads 
• Extensively found on all types of heavy- and light-rail cars, rapid transit cars, diesel-electric locomotives, freight cars and off-road vehicles 

Features: 
• Dual temperature rating at 125ºC/110ºC for long life, higher ampacities and protection from thermal overloads 
• Excellent flexibility & free stripping 
• Outstanding thermal stability at elevated temperatures 
• Maximum flame retardance and low toxicity 
• Excellent low-temperature performance; suitable for installation in sub-zero conditions 
• Extra-tough, mechanically rugged irradiated thermoset insulation 
• Resistant to most oils and chemicals 
• Meets cold bend test at –55ºC 
• Meets cold impact test at –40ºC 

Compliances: 
Industry: 
• AAR S-501/AAR RP-585 
• ICEA S-95-658 
• RoHS Compliant 

Flame Test: 
• IEEE 1202 (70,000 BTU/hr) 
• IEEE 383 (70,000 BTU/hr) 
• VW-1 

Other: 
• BSS 7239 
• SMP 800-C 
• ASTM E662 
• NFPA 130 STD 2010 
• ASTM 1354 

Packaging: Standard reel put-up


technical specification:
conductor size(awg/kcmil) 777
conductor stranding 1925/24
nominal conductor diameter(inches) 1.075
nominal conductor diameter(mm) 27.31
nominal insulation thickness(mils) 80
nominal insulation thickness(mm) 2.03
nominal cable diameter(inches) 1.235
nominal cable diameter(mm) 31.37
copper weight(lbs./1000') 2435
copper weight(kg/km)
3624
net cable weight(lbs./1000) 2564
net cable weight(kg/km) 3816
ampacity(free air 40?c ambient)110?c
1047
ampacity(free air 40?c ambient)125?c 1130
catalog number stock* 355460

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.