Prysmian and Draka Cable 8 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI4-08-010X
Select gauge from drop-down menu for prices:
- Prysmian and Draka Cable Fire Resistant Indoor and Outdoor Flame Retardant Halogen Free Loose Tube Cable QFCI/O/RM-JM
- Prysmian and Draka Cable 2 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI2-02R-010X
- Prysmian and Draka Cable 4 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI4-04-010X
- Prysmian and Draka Cable 6 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI6-06-010X
- Prysmian and Draka Cable 10 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI2-10-010X
- Prysmian and Draka Cable 12 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI6-12-010X
- Prysmian and Draka Cable 16 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI4-16-010X
- Prysmian and Draka Cable 20 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI4-20-010X
- Prysmian and Draka Cable 24 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI6-24-010X
- Prysmian and Draka Cable 32 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI8-32-010X
- Prysmian and Draka Cable 40 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI8-40-010X
- Prysmian and Draka Cable 48 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI8-48-010X
Applications:
• Optical cable for indoor and outdoor use in vital communication and emergency systems that need to be operational during fire. The cable has a patented design that ensures operation for more than 3 hours in fires up to 1000ºC. The cable is halogen free and flame retardant to protect against secondary damage to electronic equipment during and after fire. Outer sheath is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel, petrol, glycol, ethanol, white spirit and ASTM oil 2.
• The resistance to these fluids is according to DOD-STD-1678, method 8030. The cable is reinforced with a steel wire braiding. The fibers are protected in gel-filled loose tubes stranded around a central strength member to ensure optimum performance and long life. Each fiber and loose tube is color coded for easy identification during splicing and termination. The outer sheath is marked to show fiber type and cable type.
Cable Properties:
Tensile strength: (IEC 60794-1-2E1)
• Max tensile load during installation - 1500 N
• Max tensile load during operation - 500 N
Color Coding: (TIA/EIA-455-598C)
Crush: (IEC 60794-1-2E3 - 3000 N/10cm
Impact: (IEC 60794-1-2E4) - 20 impacts, 5J
Torsion: (IEC 60794-1-2E7) - ± 1 turn/1m
Cable bending:
• Minimum bending diameter - 250 mm
• Cable bend (IEC 60794-1-2E11) - < 0.1dB/ ±5 turn
Temperature window:
• Operation -30°C to +60°C
• Installation -10°C to +60°C
• Storage -40°C to +70°C
Chemical resistance:
• Mineral oils IRM 902 (IEC60811-2-1) - 7 days/23°C and 4 hours/70°C
• Diesel - IRM 903 (IEC60811-2-1) - 7 days/23°C and 4 hours/70°C
Fire and smoke classifications:
• IEC 60331-25 (750°C, 3 hours) - <1 dB excess loss
• Upgraded IEC 60331-25 (1000°C, 3 hours) - <1.5 dB excess loss
• BP-236
• IEC 61034
• IEC 60332-3 cat. A and C
• IEC 60754-1
• IEC 60754-2
technical specification: | |
number of fibers | 8 |
number of fibers in each tube | 4 |
number of tubes + fillers
|
2+4 |
loose tube diameter (mm) | 2.2 |
outer diameter (mm) | 14.3 |
weight (kg/km) | 307 |
heat release (mj/km) | 1381 |
prysmian and draka cable part number | QFCI4-08-010X |