Service Wire 2 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW2BK
Select gauge from drop-down menu for prices:
- Service Wire USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable
- Service Wire 14 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW14BK
- Service Wire 12 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW12BK
- Service Wire 10 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW10BK
- Service Wire 8 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW8BK
- Service Wire 6 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW6BK
- Service Wire 4 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW4BK
- Service Wire 3 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW3BK
- Service Wire 1 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW1BK
- Service Wire 1/0 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW1/0BK
- Service Wire 2/0 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW2/0BK
- Service Wire 3/0 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW3/0BK
- Service Wire 4/0 AWG USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW4/0BK
- Service Wire 250 MCM USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW250BK
- Service Wire 300 MCM USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW300BK
- Service Wire 350 MCM USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW350BK
- Service Wire 400 MCM USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW400BK
- Service Wire 500 MCM USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW500BK
- Service Wire 600 MCM USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW600BK
- Service Wire 750 MCM USE-2 or RHH/RHW-2 VW-1 CT Rated 600 Volt Copper Cable XHVW750BK
Description: Single copper conductor, stranded and insulated with moisture and heat resistant, chemically crosslinked polyethylene. Available in colors.
Application: Suitable for use in general purpose wiring applications and may be installed in raceway, conduit, direct burial and aerial installations where a cable having superior flame retardance is required. Suitable for use in 105ºC dry systems. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade).
Standards:
ASTM Standards:
• B-3 (soft or annealed)
• B-8 (concentric lay stranded)
• B787 (combination strand)
• UL 44 and UL 854
• C(UL)US RW90 1kV: CSA/UL Listed
• C(UL) RPV90 600V
• ICEA S-95-658/NEMA WC-70
• L-824C (#12AWG - 4/0)
• Federal Spec. A-A-59544
• Flame Rated: CT Use/IEEE 1202 (1/0 AWG and larger)
• FT-4 (1/0 AWG and larger)
• Temperature Rated at 90ºC Wet/Dry
• Cold Temperature Rated at -40°C
• Sunlight Resistant (#6 AWG and larger)
• Gasoline and Oil Resistant II
• Direct Burial
• RoHS Compliant
technical specification: | |
size awg or kcmil
|
2 |
strand (no.) | 7 |
insulation thickness (mils)
|
45 |
nominal diameter overall (inch)
|
0.374 |
approx. net weight (lb/1000') | 238 |
ampacity* 90°c wet/dry | 190 |