Service Wire 3/0 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV3/0
Select gauge from drop-down menu for prices:
- Service Wire EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHH or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable
- Service Wire 16 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV16
- Service Wire 14 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV14
- Service Wire 12 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV12
- Service Wire 10 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV10
- Service Wire 8 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV8
- Service Wire 6 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV6
- Service Wire 4 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV4
- Service Wire 3 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV3
- Service Wire 2 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV2
- Service Wire 1 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV1
- Service Wire 1/0 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV1/0
- Service Wire 2/0 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV2/0
- Service Wire 4/0 AWG EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV4/0
- Service Wire 250 MCM EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV250
- Service Wire 300 MCM EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV300
- Service Wire 350 MCM EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV350
- Service Wire 400 MCM EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV400
- Service Wire 500 MCM EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV500
- Service Wire 600 MCM EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV600
- Service Wire 750 MCM EnviroPlus Photovoltaic Wire ServiceSolar USE-2 or RHW-2 Zero Halogen Limited Smoke Jacket 600V Copper Cable PVENV750
Description: Single conductor insulated with heat and moisture resistant, crosslinked polyethylene insulation (type RHW-2), with an overall flame and sunlight resistant, zero halogen, limited smoke, zero lead jacket.
Application: Suitable for use as interconnection wiring on solar panels in grounded or ungrounded systems as defined in applicable parts of the National Electrical Code (NEC) NFPA 70, such as article 690.31(A).
Standards:
• UL 4703 and UL854 (#16 per UL 66)
• C(UL) RPV90 600V
• ICEA S-95-658/NEMA WC-70
• Flame Rated: VW-1/FT1
• CT Use (1/0 AWG and larger)
• Sunlight, Water, Crush and Abrasion Resistant
• Temperature Rated at 90°C Wet/Dry
• Cold Temperature Rated at -40°C
• Direct Burial
• Zero Halogen, Limited Smoke Jacket
• RoHS Compliant
technical specification: | |
size awg or kcmil | 3/0 |
strand (no.) | 19 |
insulation thickness (mils) | 80 |
jacket thickness (mils)
|
60 |
nominal diameter overall (inch)
|
0.73 |
approx. net weight (lb/1000') | 673 |
ampacity* (30°c ambient) 90°c wet/dry
|
225 |
service wire part number | PVENV3/0 |