Superior Essex Cable 250 MCM 3 Conductor PVC/Nylon/PVC 600V Power Type TC-ER Unshielded Cable E3BEA-A11B03CE00

Superior Essex Cable 250 MCM 3 Conductor PVC/Nylon/PVC 600V Power Type TC-ER Unshielded Cable E3BEA-A11B03CE00

Select gauge from drop-down menu for prices:

Superior Essex Cable 250 MCM 3 Conductor PVC/Nylon/PVC 600V Power Type TC-ER Unshielded Cable E3BEA-A11B03CE00

Product Details

Superior Essex Cable 250 MCM 3 Conductor PVC/Nylon/PVC 600V Power Type TC-ER Unshielded Cable E3BEA-A11B03CE00

The Superior Essex PVC/Nylon/PVC, 600V Power, Type TC-ER Cable consist of fully annealed bare copper Class B stranded conductors, covered with Polyvinyl Chloride (PVC) and Nylon insulation, unshielded and black PVC jacket. These cables are used in industrial power.

Features:
• Rated at 75°C wet or 90°C dry
• Ripcord (for jackets with thicknesses of 60-mils or less)
• Excellent sunlight resistance
• Smallest OD available for suitable applications
• Meets cold bend test at -25°C

Specifications:
Conductor Count: Available in 3 or 4 conductors

Conductor: Fully annealed bare copper Class B compressed strand per ASTM B8

Gauge Sizes: Available in 12 AWG through 750 kcmil

Insulation: Polyvinyl Chloride (PVC) covered with Nylon
• All gauges are type THHN/THWN-2

Color Coding: Per ICEA S-58-679 Method 4 or Method 1, Table E-1 (K-1) or E-2 (K-2); additional color coding options available

Fillers: Non-hygroscopic fillers, as necessary to obtain a round finish conductor

Ground Conductor: Uninsulated bare copper ground

Jacket: Polyvinyl Chloride (PVC)

Jacket Marking: 00000 FT SUPERIOR ESSEX XXAWG XX/C THHN/THWN PVC JKT 600V 90C DRY OR 75C WET TYPE TC-ER (UL) SUN RES DIR BURIAL FT4/IEEE1202 MADE IN USA MMDDYYYY

Packaging: Non-returnable wood reels in a variety of lengths and dimensions

Performance Compliances: 
• ASTM B8
• ASTM B33
• UL® 83
• UL 1277
• UL 1685 (flame compliance)
• ICEA S-95-658
• CSA FT4/IEEE1202(flame compliance)
• NEC

Other Compliances: 
• EPA 40 CFR, Part 261
• OSHA
• RoHS-compliant/RoHS 2-compliant
• REACH-compliant

Applications:
• In conduit, duct, free air, raceways and direct burial, primary installations include cable trays, and outdoor locations
• In wet or dry locations
• Approved for Class I, Div. 2 industrial hazardous locations per NEC
• Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors

technical specification:
conductor size awg/kcmil
250
conductor count 3
ground size awg 4
nominal insulation thickness¹ in (mm) 0.070 (1.78)
nominal jacket thickness¹ in (mm)
0.110 (2.79)
nominal overall diameter¹ in (mm) 1.79 (45.47)
nominal net weight¹ lbs/kft (kg/km) 3,196 (4,762)
superior essex cable part number E3BEA-A11B03CE00

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question