General Cable Type P 8 AWG MOR Polyrad® XT 125 Flexible Variable Frequency Drive Power Armored Sheathed 2 kV/1000 V

General Cable Type P 8 AWG MOR Polyrad® XT 125 Flexible Variable Frequency Drive Power Armored Sheathed 2 kV/1000 V

Select gauge from drop-down menu for prices:

General Cable Type P 8 AWG MOR Polyrad® XT 125 Flexible Variable Frequency Drive Power Armored Sheathed 2 kV/1000 V
TYPE P 8 AWG MOR POLYRAD XT 125 FLEXIBLE VARIABLE FREQUENCY DRIVE POWER ARMORED SHEATHED 2 KV/1000 V

Conductor: 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand 

Insulation: 
• Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) 
• Color Code: All black with printed numbers 

Ground: 3 split green insulated flexible tinned copper conductors sized to UL 1277 

Shield: Overall tinned copper braid with aluminum/polyester tape – 100% coverage for enhanced shield effectiveness required by VFD applications 

Jacket: Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) 

Armor: Bronze braid 88% minimum coverage 

Sheath: Mud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) 

Option: 
• Full-sized insulated ground wires 
• Uninsulated ground wires 

Applications: 
• AC motor variable frequency drives 
• Offshore oil and gas drilling platforms, MODUs, ships and FPSOs 
• Land-based oil and gas drilling rigs 
• Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F 

Features: 
• Meets NEK 606 mud oil resistance requirements with ester-based muds 
• Meets UL 2225 crush and impact requirements of Type MC-HL cables 
• Flexible stranding to facilitate ease of cable installation and termination 
• Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads 
• Meets cold bend test at -55°C 
• Meets cold impact test at -40°C 

Compliances: 
Industry: 
• API-RP14F 
• CSA C22.2 No. 245 Type X110 
• IEEE 1580-2010 Type P 
• IEC 60092-350 
• Mud oil-resistant 
• UL 1309 Type X110 
• UL Listed 110°C Marine Shipboard Cable 

Flame Test: 
• IEEE 1202 
• IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) 
• CSA C22.2 No. 0.3 FT4

technical specifications:
cond.size(awg) 8
# of cores 3
grounding cond. size(awg) 3 x #14
nominal cable diameter(inches) 1.170
nominal cable diameter(mm) 29.72
copper weight(lbs/1000 ft) 226
copper weight(kg/km) 336
net weight(lbs/1000 ft) 903
net weight(kg/km) 1344
ampacities1 45°c ambient-single banked(95°c) 50
ampacities1 45°c ambient-single banked(100°c) 52
ampacities1 45°c ambient-single banked(110°c) 56
ampacities1 45°c ambient-single banked(125°c) 63
catalog number 381820ig