Prysmian and Draka Cable BFCU(C) 250V Instrumentation Collective Screened Fire Resistant, Flame Retardant, Halogen free, Armoured Cable

Prysmian and Draka Cable BFCU(C) 250V Instrumentation Collective Screened Fire Resistant, Flame Retardant, Halogen free, Armoured Cable

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable BFCU(C) 250V Instrumentation Collective Screened Fire Resistant, Flame Retardant, Halogen free, Armoured Cable

Product Details

Conductor:
• Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)
• Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)

Insulation: Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2

Pair/Triple/Quad twisting: Colour coded cores twisted together to form a pair, triple or quad, wrapped with polyester tape. Pairs, triples or quads are laid up, collectively screened with a aluminum backed polyester tape with tinned copper drain wire. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors.

Inner Covering: Flame retardant and halogen-free thermoplastic EP-rubber based compound

Tape Over Inner Covering: PET tape + rubberized Polyamide tape

Armour/Screen: Galvanized steel wire braid

Tape Over Armour/Screen: PET tape + rubberised Polyamide tape

Outer Sheath: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking Text: "metre mark" "year" "DRAKA" "BFCU(C)" "UKOOA code" "150/250V" "number of paris, triples or quads" "conductor size" "BS7917" "IEC60331-21" "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer Sheath Colour: Grey or Blue

Core Identification:
• Pair - Black-White, numbered 1-1, 2-2, 3-3....
• Triple - Black-White-Red, numbered 1-1-1, 2-2-2, 3-3-3.....
• Quad - Black-White-Red-Blue, numbered 1-1-1-1, 2-2-2-2.....
• Each core is identified by constrasting number & words repeated along the whole length of the cable.

Operating Temperature: 90°C

Operating Voltage: 250V

Standards applied:
• BS7917/BS6883/UKOOA - Design
• BS6360 class 2 or 5 - Conductor
• BS7655 section 1.2 - Insulation
• BS7655 section 2.6 - Sheath
• IEC 60332-1 & 3-22 - Flame Retardant
• IEC60331-21 - Fire Resistant
• IEC60754-1,2 - Halogen Free
• IEC 61034-1,2 - Low Smoke

Description:
• BFCU(C) 250V 2PAIR 0.75mm2
• BFCU(C) 250V 2PAIR 0.75mm2
• BFCU(C) 250V 3PAIR 0.75mm2
• BFCU(C) 250V 3PAIR 0.75mm2
• BFCU(C) 250V 5PAIR 0.75mm2
• BFCU(C) 250V 5PAIR 0.75mm2
• BFCU(C) 250V 7PAIR 0.75mm2
• BFCU(C) 250V 7PAIR 0.75mm2
• BFCU(C) 250V 12PAIR 0.75mm2
• BFCU(C) 250V 12PAIR 0.75mm2
• BFCU(C) 250V 19PAIR 0.75mm2
• BFCU(C) 250V 19PAIR 0.75mm2
• BFCU(C) 250V 20PAIR 0.75mm2
• BFCU(C) 250V 20PAIR 0.75mm2
• BFCU(C) 250V 27PAIR 0.75mm2
• BFCU(C) 250V 27PAIR 0.75mm2
• BFCU(C) 250V 3PAIR 1mm2
• BFCU(C) 250V 3PAIR 1mm2
• BFCU(C) 250V 2PAIR 1.5mm2
• BFCU(C) 250V 2PAIR 1.5mm2
• BFCU(C) 250V 3PAIR 1.5mm2
• BFCU(C) 250V 3PAIR 1.5mm2
• BFCU(C) 250V 5PAIR 1.5mm2
• BFCU(C) 250V 5PAIR 1.5mm2
• BFCU(C) 250V 7PAIR 1.5mm2
• BFCU(C) 250V 7PAIR 1.5mm2
• BFCU(C) 250V 12PAIR 1.5mm2
• BFCU(C) 250V 12PAIR 1.5mm2
• BFCU(C) 250V 20PAIR 1.5mm2
• BFCU(C) 250V 20PAIR 1.5mm2
• BFCU(C) 250V 27PAIR 1.5mm2
• BFCU(C) 250V 3PAIR 2.5mm2
• BFCU(C) 250V 12PAIR 2.5mm2
• BFCU(C) 250V 3TRIP 0.75mm2
• BFCU(C) 250V 7TRIP 0.75mm2
• BFCU(C) 250V 12TRIP 0.75mm2
• BFCU(C) 250V 2TRIP 1.5mm2
• BFCU(C) 250V 7TRIP 1.5mm2
• BFCU(C) 250V 12TRIP 1.5mm2

Sheath Colour:
• BLUE
• GREY

Design Standard:
• BS 6883 : 1991
• BS 7917 : 1999

Application:
• Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where there is a requirement for fire resistant cables.
• Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.