General Cable Type PLTC 16/24 Gauge Individual and Overall Shielded Pairs CHTC® XLPE TL-CPE Instrumentation Shielded 300V UL

General Cable Type PLTC 16/24 Gauge Individual and Overall Shielded Pairs CHTC® XLPE TL-CPE Instrumentation Shielded 300V UL

Select gauge from drop-down menu for prices:

General Cable Type PLTC 16/24 Gauge Individual and Overall Shielded Pairs CHTC® XLPE TL-CPE Instrumentation Shielded 300V UL

Product Details

Type PLTC 16/24 Gauge Individual and Overall Shielded Pairs CHTC XLPE TL-CPE Instrumentation Shielded 300V UL

Conductor:
• 20 AWG thru 16 AWG tinned, annealed copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:
• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black and white. One conductor in each pair is printed alphanumerically for easy identification

Shield:
Individual and overall shielded pairs
• Individual pairs are 100% shielded with Flexfoil® aluminum/polyester in contact with stranded tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in contact with stranded tinned copper drain wire

Jacket: Lead-free Cross-linked Chlorinated Polyethylene (XL-CPE)

Applications:
• Typical applications include audio, intercom, control, energy management and alarm circuits
• In free air or raceways in accordance with NEC
• Permitted for use in Class I, Division 2 industrial hazardous locations per NEC
• In ducts, cable trays or conduit
• In accordance with UL Subject 13 as PowerLimited Circuit Cable
• In class 3 circuits in accordance with NEC

Features:
• Rated at 90?C
• Ripcord applied to all cables with jacket thickness of 60 mils or less
• Oil-resistant jacket
• Sunlight- and weather-resistant
• Excellent electrical, thermal and physical properties
• Excellent moisture resistance
• Excellent flame resistance
• “Heavy duty” rating per ICEA standards
• Excellent low temperature cold bend characteristics
• Meets cold bend test at -40?C

Compliances:
Industry Compliances:
• UL 13 Type PLTC, UL File # E36118
• UL 1581
• RoHS Compliant

Flame Test Compliances:
• UL 1581/UL 2556 VW-1
• IEEE 383
• IEEE 1202
• CSA FT4

Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable

Packaging: Material cut to length and shipped on non-returnable wood reels

technical specification:
cond. size (awg) 16
no. of pairs 24
cond. strand 7W
minimum avg. insulation thickness(inches) 0.015
minimum avg. insulation thickness(mm) 0.38
minimum avg. jacket thickness(inches) 0.070
minimum avg. jacket thickness(mm) 1.78
nominal cable o.d.(inches) 1.235
nominal cable o.d.(mm) 31.37
copper weight(lbs/1000 ft) 455
copper weight(kg/km) 677
net weight(lbs/1000 ft) 800
net weight(kg/km) 1191
catalog number 338220*

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question