TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 1/0 AWG
Select gauge from drop-down menu for prices:
TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 1/0 AWG
- Type UF/NMC-B Cable 600 Volt, Multi Conductor With or Without Ground
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 14 AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 12 AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 10 AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 8 AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 6 AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 4 AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 2 AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 2/0 AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 3/0 AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 4/0 AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 14 AWG - 2 Conductors
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 12 AWG - 2 Conductors
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 10 AWG - 2 Conductors
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 8 AWG - 2 Conductors
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 6 AWG - 2 Conductors
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 14 AWG - 3 Conductors
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 12 AWG - 3 Conductors
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 10 AWG - 3 Conductors
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 8 AWG - 3 Conductors
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 6 AWG - 3 Conductors
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 14 AWG - 2 Conductors - 14 Ground Size AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 12 AWG - 2 Conductors - 12 Ground Size AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 10 AWG - 2 Conductors - 10 Ground Size AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 8 AWG - 2 Conductors - 10 Ground Size AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 6 AWG - 2 Conductors - 10 Ground Size AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 14 AWG - 3 Conductors - 14 Ground Size AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 12 AWG - 3 Conductors - 12 Ground Size AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 10 AWG - 3 Conductors - 10 Ground Size AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 8 AWG - 3 Conductors - 10 Ground Size AWG
- TYPE UF / NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 6 AWG - 3 Conductors - 10 Ground Size AWG
Product Details
Technical Specifications: | |
Conductor Size AWG | 1/0 |
Number of Insulated Conductors | N/A |
Ground Size AWG | -- |
Power Conductor Stranding | 19/.0745 |
Insulation Thickness (Inches) | 0.095 |
Insulation Thickness (mm) | 2.413 |
Jacket Thickness (Inches) | -- |
Jacket Thickness (mm) | -- |
Cable O.D. (Inches) | 0.573 |
Cable O.D. (mm) | 14.544 |
Cable Weight lb/mft | 415 |
Ampacity UF or NMC-B 60 Degrees C | 125 |
Specifications:
- TYPE UF / NMC-B CABLE
- 600 VOLT, 2 AND 3 CONDUCTOR
- WITH OR WITHOUT GROUND
- 60°C Dry/Wet
Applications:
Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.
Features:
UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays
INSULATION:
POLYVINYL CHLORIDE (PVC)
JACKET:
POLYVINYL CHLORIDE (PVC)