Prysmian and Draka Cable 4 Cores 2.5 Cross-section core RU 0.6/1kV Unarmoured Power Cable 840307
Select gauge from drop-down menu for prices:
- Prysmian and Draka Cable RU 0.6/1kV Unarmoured Power Cable
- Prysmian and Draka Cable 2 Cores 1.5 Cross-section core RU 0.6/1kV Unarmoured Power Cable 840300
- Prysmian and Draka Cable 2 Cores 2.5 Cross-section core RU 0.6/1kV Unarmoured Power Cable 840301
- Prysmian and Draka Cable 3 Cores 1.5 Cross-section core RU 0.6/1kV Unarmoured Power Cable 840302
- Prysmian and Draka Cable 3 Cores 2.5 Cross-section core RU 0.6/1kV Unarmoured Power Cable 840303
- Prysmian and Draka Cable 3 Cores 4 Cross-section core RU 0.6/1kV Unarmoured Power Cable 840304
- Prysmian and Draka Cable 3 Cores 6 Cross-section core RU 0.6/1kV Unarmoured Power Cable 840305
- Prysmian and Draka Cable 3 Cores 10 Cross-section core RU 0.6/1kV Unarmoured Power Cable 840312
- Prysmian and Draka Cable 3 Cores 16 Cross-section core RU 0.6/1kV Unarmoured Power Cable 840313
- Prysmian and Draka Cable 4 Cores 1.5 Cross-section core RU 0.6/1kV Unarmoured Power Cable 840306
Conductor: Tinned stranded circular copper, BS6360, class 2
Insulation: EP-rubber, GP4 to BS7655:section 1.2
Inner sheath: No inner sheath, additional tapes may be applied
Armour/screen: No armour
Outer sheath: Flame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF) SW4 to BS7655 section 2.6. (Mud resistant version available on request)
Marking text: "meter mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS6883" "IEC60332-3-32" (marking may differ on cable actually supplied)
Outer sheath colour: Black
Core identification: All cores are offwhite with black numbers No 1,2,3....
Operating tempeature: 90°C
Operating Voltage: 0.6/1kV
Description:
• RU 0.6/1kV 2X 1.5mm2
• RU 0.6/1kV 2X 2.5mm2
• RU 0.6/1kV 3X 1.5mm2
• RU 0.6/1kV 3X 2.5mm2
• RU 0.6/1kV 3X 4mm2
• RU 0.6/1kV 3X 6mm2
• RU 0.6/1kV 3X 10mm2
• RU 0.6/1kV 3X 16mm2
• RU 0.6/1kV 4X 1.5mm2
• RU 0.6/1kV 4X 2.5mm2
Sheath Colour: BLACK
Design standard: BS 6883:1999
Standards applied:
• BS6883 - Design
• BS6360 class 2 - Conductor
• BS7655 section 1.2 - Insulation
• BS7655 section 2.6 - Sheath
• IEC 60332-1 - Flame Retardant
• IEC60332-3-22 - Flame retardant
• IEC60754-1,2 - Halogen Free
• IEC 61034-1,2 - Low Smoke
Application:
• Unarmoured cable for fixed installation where cable protection is not required. Power, control and lighting in safe areas.
• Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement n NEK 606.
technical specification: | |
number of cores | 4 |
cross section core, mm2 | 2.5 |
conductor diameter, mm | 2 |
insulation thickness, mm | 0.8 |
thickness outer sheath, mm | 1.1 |
approx. overall diameter, mm | 11 |
approx. weight of cable (kg/km) | 220 |
copper content approx. (kg/km) | 92 |
max. conductor resistance at 20°c, ohm/km | 7.56 |
max. conductor resistance at 90°c, ohm/km | 9.64 |
reactance at 50hz, ohm/km | 0.096 |
reactance at 60hz, ohm/km | 0.115 |
current rating iec 60092-352 table b.4, ampere | 21 |
short circuit rating 1 second, ampere | 350 |
prysmian and draka cable part number | 840307 |